multiple socket outlet PV4-MID-PS

Warning

Risk of injury by unintentional start-up of consumers!
Electronic devices connected to the multiple socket
outlet can start up automatically and cause injuries
when a triggered residual current device restarts.
Only switch on the residual current device after having
switched off the connected devices or after having
disconnected them from the multiple socket outlet.

Maintenance

Visual inspection

Check the device for external damage before every start-up.
Should you detect any damage at the device or its mains cable,
have it fixed by a qualified electrician.

Regular inspections

Warning of electrical voltage

Work on the electrical components must only be
carried out by a qualified electrician!

Warning of electrical voltage

There is a risk of an electric shock when touching
damaged, open or live parts.
Never clean a live socket.
Always disconnect the mains plug from the socket
before cleaning it.
Never immerse the multiple socket outlet in water!
Clean the multiple socket outlet with a dry cloth.

The device must be regularly checked by a qualified electrician
for proper functioning and proper condition. If used in office
spaces or similar ambient conditions, this inspection shall be
carried out at least every 2 years. If used on construction and
installation sites, the inspection shall be carried out 
every 3 months. If an error rate of < 2 % is reached, the
inspection intervals may be extended to max. once per year.

Checking the residual current device

Info

Generally, the power supply of all consumers is
interrupted for testing the residual current device.
Make sure that – when testing the residual current
device – no currently required consumer is connected
to the device.

The proper functioning of the residual current device (7) needs
to be checked at intervals of approx. 3 months.
The functionality can be checked by means of the test button

T

 (2) every residual current device is equipped with.

If you press the test button 

T

 (2), an artificial residual current

will be generated and the residual current device (7) has to trip.
Also observe the inspection intervals specified in the regulations
and provisions (e.g. accident prevention regulations).

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Содержание PV4-MID-PS

Страница 1: ...TRT BA PV4 MID PS TC2019 63 001 EN PV4 MID PS EN OPERATING MANUAL MULTIPLE SOCKET OUTLET...

Страница 2: ...mediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious...

Страница 3: ...bed in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Intended use The device serves as mobile multiple socket outlet The multiple socket outlet...

Страница 4: ...e description The device serves for the mobile power supply on varying application devices It comes with the following device characteristics 4 safety sockets CEE 7 3 with one PlugSafe appliance each...

Страница 5: ...t for seal 10 Safety socket cover 11 PlugSafe appliance 12 Seal 13 Anchoring for seal 14 Open end of seal 15 Terminals for neutral conductors 16 Multifunction button 17 Metrological LED 18 Backlit LC...

Страница 6: ...20 mA Accuracy Active energy class B according to EN 50470 3 MID Active energy class 1 according to EN 62053 21 NO MID Reactive energy class 2 according to EN 62053 23 S0 output Passive optoisolated...

Страница 7: ...orage temperature is the same as the range given in the Technical data chapter Start up Warning of electrical voltage Work on the electrical components must only be carried out by a qualified electric...

Страница 8: ...unauthorised access by means of one or more seals 12 Securing the multiple socket outlet can be realised whether a plug has been inserted into the safety socket 5 or not One seal 12 per plug or safet...

Страница 9: ...nctions or settings are controlled via the multifunction button 16 The symbol indicates a standard value the indicates a bidirectional value All total counter values kWh kVAh kvarh can be assigned to...

Страница 10: ...nter records the total consumption If required the partial counter can be activated in addition to record a value during a certain period of time The partial counter can be started stopped and reset 1...

Страница 11: ...unction button 16 for 3 s During these 3 seconds 3 bars will be displayed next to the Stop sequence Once the Stop sequence is completely indicated the partial counter will be stopped The symbol will b...

Страница 12: ...enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe t...

Страница 13: ...is reached the inspection intervals may be extended to max once per year Checking the residual current device Info Generally the power supply of all consumers is interrupted for testing the residual...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: