multiple socket outlet PV4-MID-PS

Device depiction

kW

h

kW

h

5

1

4

2 3

8

7

9

6

11

10

Seal

13

14

12

MID-compliant energy meter

17

15

16

18

20

19

21

21

22

26

23

25

24

27

28

29

30

31

16

17

No.

:

Designation

1

Sealing cap

2

Test button 

T

3

MID-compliant energy meter

4

Robust solid rubber housing

5

Safety socket

6

Handle

7

Residual current device

8

Locking lug for sealing cap

9

Eyelet for seal

10

Safety socket cover

11

PlugSafe appliance

12

Seal

13

Anchoring for seal

14

Open end of seal

15

Terminals for neutral conductors

16

Multifunction button

17

Metrological LED

18

Backlit LC display

19

Terminals for S0 output

20

Current and voltage terminals

21

Safety label

22

Pulse value in kWh (metrological LED)

23

Min./reference current (max. continuous current)

24

Nominal voltage/ frequency

25

Connection diagram (1 phase and neutral conductor)

26

Type of protection

27

Serial number

28

MID designation

29

Homologation number

30

Accuracy class

31

Operating temperature range

Содержание PV4-MID-PS

Страница 1: ...TRT BA PV4 MID PS TC2019 63 001 EN PV4 MID PS EN OPERATING MANUAL MULTIPLE SOCKET OUTLET...

Страница 2: ...mediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious...

Страница 3: ...bed in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Intended use The device serves as mobile multiple socket outlet The multiple socket outlet...

Страница 4: ...e description The device serves for the mobile power supply on varying application devices It comes with the following device characteristics 4 safety sockets CEE 7 3 with one PlugSafe appliance each...

Страница 5: ...t for seal 10 Safety socket cover 11 PlugSafe appliance 12 Seal 13 Anchoring for seal 14 Open end of seal 15 Terminals for neutral conductors 16 Multifunction button 17 Metrological LED 18 Backlit LC...

Страница 6: ...20 mA Accuracy Active energy class B according to EN 50470 3 MID Active energy class 1 according to EN 62053 21 NO MID Reactive energy class 2 according to EN 62053 23 S0 output Passive optoisolated...

Страница 7: ...orage temperature is the same as the range given in the Technical data chapter Start up Warning of electrical voltage Work on the electrical components must only be carried out by a qualified electric...

Страница 8: ...unauthorised access by means of one or more seals 12 Securing the multiple socket outlet can be realised whether a plug has been inserted into the safety socket 5 or not One seal 12 per plug or safet...

Страница 9: ...nctions or settings are controlled via the multifunction button 16 The symbol indicates a standard value the indicates a bidirectional value All total counter values kWh kVAh kvarh can be assigned to...

Страница 10: ...nter records the total consumption If required the partial counter can be activated in addition to record a value during a certain period of time The partial counter can be started stopped and reset 1...

Страница 11: ...unction button 16 for 3 s During these 3 seconds 3 bars will be displayed next to the Stop sequence Once the Stop sequence is completely indicated the partial counter will be stopped The symbol will b...

Страница 12: ...enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe t...

Страница 13: ...is reached the inspection intervals may be extended to max once per year Checking the residual current device Info Generally the power supply of all consumers is interrupted for testing the residual...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: