Trotec PV4-MID-PS Скачать руководство пользователя страница 3

EN

3

multiple socket outlet PV4-MID-PS

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. If the
supply cord is damaged, it must be replaced by the
manufacturer, his service agent or similarly qualified
persons in order to avoid a hazard. Defective power cables
pose a serious health risk!

Always plug in only one device per socket and never cover
the multiple socket outlet.

Multiple socket outlet plugs must match the outlet. Never
modify the plug in any way. Do not use any adapter plugs
with earthed (grounded) electrical devices. Unmodified
plugs and matching outlets will reduce risk of electric
shock.

Do not force the power tool. Only use the device with the
capacity range specified on the nameplate.

Observe the storage and operating conditions as given in
the Technical data chapter.

Do not expose the device to heat or direct sunlight.

Do not manipulate the device and do not make any
adaptations to the multiple socket outlet.

Always plug in only one device per socket and do not cover
the multiple socket outlet during operation.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Intended use

The device serves as mobile multiple socket outlet. 
The multiple socket outlet is suitable for indoor and outdoor
applications. 
Only use multiple socket outlets matching the protection type
required at the application site. 
The device may only be used on grounded sockets of the
installation site.
The device may only be used complying with the voltage and
capacity range specified on the nameplate of the device.
When operating the device on construction or installation sites
at sockets of the building's site with unknown protective
measures, a BGI608-compliant plug adapter must be used. 
Only qualified electricians are allowed to perform repair work on
the multiple socket outlet.

Improper use

Any unauthorised changes, modifications or alterations to the
device are forbidden.
Do not use the device in potentially explosive areas. Do not
place the device on wet or flooded ground.

Personnel qualifications

People who use this device must:

have read and understood the operating manual, especially
the Safety chapter.

Initial start-up and maintenance tasks which require the
housing to be opened must only be carried out by qualified
electricians.

Electrically skilled person

Electrically skilled personnel must be able to read and
understand electric circuit diagrams, to put electrical systems
into service and to maintain them, to wire control cabinets, to
ensure the functionality of electrical components and to identify
possible hazards from electrical and electronic systems.

Содержание PV4-MID-PS

Страница 1: ...TRT BA PV4 MID PS TC2019 63 001 EN PV4 MID PS EN OPERATING MANUAL MULTIPLE SOCKET OUTLET...

Страница 2: ...mediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious...

Страница 3: ...bed in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Intended use The device serves as mobile multiple socket outlet The multiple socket outlet...

Страница 4: ...e description The device serves for the mobile power supply on varying application devices It comes with the following device characteristics 4 safety sockets CEE 7 3 with one PlugSafe appliance each...

Страница 5: ...t for seal 10 Safety socket cover 11 PlugSafe appliance 12 Seal 13 Anchoring for seal 14 Open end of seal 15 Terminals for neutral conductors 16 Multifunction button 17 Metrological LED 18 Backlit LC...

Страница 6: ...20 mA Accuracy Active energy class B according to EN 50470 3 MID Active energy class 1 according to EN 62053 21 NO MID Reactive energy class 2 according to EN 62053 23 S0 output Passive optoisolated...

Страница 7: ...orage temperature is the same as the range given in the Technical data chapter Start up Warning of electrical voltage Work on the electrical components must only be carried out by a qualified electric...

Страница 8: ...unauthorised access by means of one or more seals 12 Securing the multiple socket outlet can be realised whether a plug has been inserted into the safety socket 5 or not One seal 12 per plug or safet...

Страница 9: ...nctions or settings are controlled via the multifunction button 16 The symbol indicates a standard value the indicates a bidirectional value All total counter values kWh kVAh kvarh can be assigned to...

Страница 10: ...nter records the total consumption If required the partial counter can be activated in addition to record a value during a certain period of time The partial counter can be started stopped and reset 1...

Страница 11: ...unction button 16 for 3 s During these 3 seconds 3 bars will be displayed next to the Stop sequence Once the Stop sequence is completely indicated the partial counter will be stopped The symbol will b...

Страница 12: ...enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe t...

Страница 13: ...is reached the inspection intervals may be extended to max once per year Checking the residual current device Info Generally the power supply of all consumers is interrupted for testing the residual...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: