multiple socket outlet PV4-MID-PS

Starting, stopping and resetting the partial counter

The functions 

Starting and stopping the partial counter

 and

Resetting

 are only available on the partial counter page.

Starting the partial counter

1. Press the multifunction button (16) for 2 s on the page of

the partial counter that you would like to start.

ð

The partial counter page will be displayed indicating the

Start

 sequence.

2. Press the multifunction button (16) for 3 s.

ð

During these 3 seconds, 3 bars will be displayed next to
the 

Start

 sequence.

ð

Once the 

Start

 sequence is completely indicated, the

partial counter will be started. The 

 symbol will

be displayed.

ð

If you let go of the multifunction button (16) during
the 3 s, the partial counter will not be started.

Stopping the partial counter

1. Press the multifunction button (16) for 2 s to stop the

partial counter.

ð

The partial counter page will be displayed indicating the

Stop

 sequence.

2. Press the multifunction button (16) for 3 s.

ð

During these 3 seconds, 3 bars will be displayed next to
the 

Stop

 sequence.

ð

Once the 

Stop

 sequence is completely indicated, the

partial counter will be stopped. The 

 symbol will

be displayed.

ð

If you let go of the multifunction button (16) during
the 3 s, the partial counter will not be stopped.

Resetting the partial counter

1. Press the multifunction button (16) for 2 s.

ð

According to the counter status, either 

Start

 or 

Stop

 will

be displayed.

2. Briefly press the multifunction button (16) one time.

ð

The partial counter page will be displayed indicating the

Reset

 sequence.

3. Press the multifunction button (16) for 3 s.

ð

During these 3 seconds, 3 bars will be displayed next to
the 

Reset

 sequence.

ð

Once the Reset sequence is completely indicated, the
partial counter will be reset.

ð

If you let go of the multifunction button (16) during
the 3 s, the partial counter will not be reset.

Return to the partial counter page without making
adaptations

1. Press the multifunction button (16) several times to return

to the partial counter page without having made an action
or an adaptation (

Start

Stop

 or 

Reset

).

ð

The partial counter page will be displayed.

Содержание PV4-MID-PS

Страница 1: ...TRT BA PV4 MID PS TC2019 63 001 EN PV4 MID PS EN OPERATING MANUAL MULTIPLE SOCKET OUTLET...

Страница 2: ...mediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious...

Страница 3: ...bed in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Intended use The device serves as mobile multiple socket outlet The multiple socket outlet...

Страница 4: ...e description The device serves for the mobile power supply on varying application devices It comes with the following device characteristics 4 safety sockets CEE 7 3 with one PlugSafe appliance each...

Страница 5: ...t for seal 10 Safety socket cover 11 PlugSafe appliance 12 Seal 13 Anchoring for seal 14 Open end of seal 15 Terminals for neutral conductors 16 Multifunction button 17 Metrological LED 18 Backlit LC...

Страница 6: ...20 mA Accuracy Active energy class B according to EN 50470 3 MID Active energy class 1 according to EN 62053 21 NO MID Reactive energy class 2 according to EN 62053 23 S0 output Passive optoisolated...

Страница 7: ...orage temperature is the same as the range given in the Technical data chapter Start up Warning of electrical voltage Work on the electrical components must only be carried out by a qualified electric...

Страница 8: ...unauthorised access by means of one or more seals 12 Securing the multiple socket outlet can be realised whether a plug has been inserted into the safety socket 5 or not One seal 12 per plug or safet...

Страница 9: ...nctions or settings are controlled via the multifunction button 16 The symbol indicates a standard value the indicates a bidirectional value All total counter values kWh kVAh kvarh can be assigned to...

Страница 10: ...nter records the total consumption If required the partial counter can be activated in addition to record a value during a certain period of time The partial counter can be started stopped and reset 1...

Страница 11: ...unction button 16 for 3 s During these 3 seconds 3 bars will be displayed next to the Stop sequence Once the Stop sequence is completely indicated the partial counter will be stopped The symbol will b...

Страница 12: ...enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe t...

Страница 13: ...is reached the inspection intervals may be extended to max once per year Checking the residual current device Info Generally the power supply of all consumers is interrupted for testing the residual...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: