EN
Operating Manual – Air Conditioner PT 6500 S
6
Start-up
• Check air inlet (15) and outlet (16) for foreign objects and
remove these, if necessary.
• Check the air filter for dirt and clean it, if required. See
• Ensure that the basic device and the external heat exchanger
are properly connected to each other. See Connecting basic
device and external heat exchanger on page 5.
Switching the device on
1. Insert the mains plug (14) into a properly secured mains
power socket.
2. Select the desired fan speed.
3. Select the desired room temperature.
4. Use the ON/OFF button (18) to switch the device on.
– In doing so, select the operating mode cooling or
ventilation.
Setting the operating mode
The following operating modes are available:
• cooling: The room air is circulated by the device and cooled
at the same time.
• ventilation: The room air is circulated by the device.
The operating mode is selected during switch-on of the device:
• I stands for cooling mode.
• II stands for ventilation mode.
Shutdown
1. Use the ON/OFF switch (18) to switch the device off.
2. Remove the mains plug from the mains socket.
3. Disconnect all connections between basic device and
external heat exchanger.
4. Clean the device, and especially the air filter, according to
chapter Maintenance on page 8.
5. Store the device according to chapter Storage on page 5.
Control panel
No.
Designation
Function
17
Green LED
Is illuminated as soon as the device is supplied with power.
18
ON/OFF switch
Switches the device on or off and selects the operating mode:
0: Device is switched off.
I: Device is switched on and set to cooling mode.
II: Device is switched on and set to ventilation mode.
19
Display
Indicates the operating hours of the compressor (cooling mode).
Displays
dEFr
when the device operates in defrost mode.
Indicates an error message in case of a fault. See Errors and faults on page 7.
20
Temperature switch
To select the desired room temperature for cooling mode.
21
Fan speed switch
To select the fan speed:
MIN: lowest level
MED: medium level
MAX: highest level
17
18
19
20
21
Содержание PT 6500 S
Страница 1: ...OPERATING MANUAL AIR CONDITIONER EN PT 6500 S TRT BA PT6500S TC 003 EN...
Страница 14: ......
Страница 15: ......