The accurate functionality of the device was tested during
production a number of times. If malfunctions occur nonetheless,
check the device according to the following list:
Wear safety glasses
For start-up, maintenance and fault clearance always
wear safety glasses.
Wear protective gloves
For start-up, maintenance and fault clearance always
wear protective gloves.
The device does not start:
• Check the power connection.
• Check the mains plug for damages.
• Observe the operating temperature range of +10 °C to
+30 °C.
• Have the electrics checked by a specialist company for
cooling and air-conditioning or by Trotec.
The device works with reduced or no cooling capacity:
• Check whether cooling mode is selected.
• Check the connection lines leading to the external heat
exchanger for proper fit.
• Check the air filter for dirt. Clean the air filter, if required. See
• Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre, if
required.
• Check whether there are opened windows and/or doors of
the room. Close these, if any.
• Check the temperature setting at the device. Reduce the set
temperature, if it is higher than the room temperature.
The warning message
PumP
is displayed:
• Check the condensation hose leading to the external heat
exchanger for proper fit.
• The device automatically performs a reset.
The warning message
HIPS
is displayed:
• Check the connection lines leading to the external heat
exchanger for proper fit.
• Check the filling level of the water tank.
• Check whether the fan of the external heat exchanger is
working properly. If necessary, have the fan inspected or
exchanged by a specialist company for cooling and
air-conditioning.
• Observe the operating temperature range of +10 °C to
+30 °C.
• Actuate the reset button (22), when the problem has been
resolved.
The warning message
LOPS
is displayed:
• The device automatically performs a reset.
• Check the air filter for dirt. If required, clean the air filter (see
chapter Maintenance on page 8).
• Have the device checked for leakage by a specialist company
for cooling and air-conditioning.
The device is loud or vibrates; condensate is leaking:
• Check whether the device is standing upright and on an even
surface.
The device gets very warm, is loud or is losing performance:
• Check the air inlets and air filter are not dirty. Remove
external dirt.
• Check the inside of the device and especially the fan, the fan
housing, the evaporator and the compressor for external dirt
(see chapter Maintenance on page 8). If the inside of the
device is dirty, have it cleaned by a specialist company for
cooling and air-conditioning or by Trotec.
Your device still does not operate correctly after these
checks?
Bring the device to a specialist company for cooling and
air-conditioning or to Trotec for repair.