background image

EN

Operating Manual – Air Conditioner PT 6500 S

4

Carefully read the operating manual before using the device
and keep it within reach!

• Do not use the device in potentially explosive rooms.

• Do not use the device in atmospheres containing oil, sulphur,

chlorine or salt.

• Set the device up in an upright and stable position.

• Never drink the water / glycol mixture! Dispose of the water /

glycol mixture properly!

• Let the device dry out after a wet clean. Do not operate it

when wet.

• Ensure that the air inlet and outlet are not obstructed.

• Ensure that the suction side is kept free of dirt and loose

objects.

• Never insert objects into the device.

• Never fill the tank directly from a water line. Use a suitable

vessel or other means.

• Do not cover or transport the device during operation.

• Ensure that all electric cables outside of the device are

protected from damage (e.g. from animals).

• Only use extensions to the connecting cable which are

appropriate to the device power consumption, the length of
its cable and its use. Avoid electrical overload.

• Only transport the device in an upright position.

• Do not remove any safety signs, stickers or labels from the

device. Keep all safety signs, stickers and labels in legible
condition.

• Observe the storage and operating conditions. See Technical

data on page 3.

Intended use

Use the device only for cooling and ventilating room air, while
adhering to and following the technical data.

Improper use

Do not place the device on damp or flooded ground. Do not use
the basic device outdoors. Do not place any objects, e.g. wet
clothing, on the device for drying. Any unauthorised changes,
modifications or alterations to the device are forbidden.

Personnel qualifications

People who use this device must:

• be aware of the dangers that occur when working with

electric devices in damp areas.

• have read and understood the operating manual, especially

the Safety chapter.

Personal protective equipment

Wear safety glasses

For start-up, maintenance and fault clearance always
wear safety glasses.

Wear protective gloves

For start-up, maintenance and fault clearance always
wear protective gloves.

Residual risks

Hazardous electric voltage!

Work on the electrical components must only be
carried out by an authorised specialist company!

Hazardous electric voltage!

Before any work on the device, remove the mains plug
from the mains socket!

Danger!

Keep the water / glycol mixture away from your eyes at all
times! Should the water / glycol mixture contact your
eyes, immediately rinse them with clear water!

Danger!

Never drink the water / glycol mixture! Glycol is unfit for
human consumption and harmful to health!

Danger!

Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Danger!

These devices are not toys and do not belong in the hands
of
children!

Danger!

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way.
Observe the personnel qualifications.

Caution!

To avoid damages to the device, never operate the device
without an air filter inserted!

Caution!

To avoid damages to the device, only transport and
operate the device in an upright position! It must neither
be tilted nor laid down!

Safety

Содержание PT 6500 S

Страница 1: ...OPERATING MANUAL AIR CONDITIONER EN PT 6500 S TRT BA PT6500S TC 003 EN...

Страница 2: ...uplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the...

Страница 3: ...erant cools down the air coming from the room and in doing so absorbs the heat The thusly cooled air is introduced to the room where the device is positioned via the fan Accumulating condensate is dis...

Страница 4: ...ensions external heat exchanger height x width x depth 1200 mm x 815 mm x 360 mm 510 mm x 650 mm x 320 mm Maximum distance between basic device and external heat exchanger 30 m Minimum distance of ext...

Страница 5: ...the basic device outdoors Do not place any objects e g wet clothing on the device for drying Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications...

Страница 6: ...s when laying the power cable or other lines Make sure that no curtains or other objects interfere with the air flow Ensure that extension cords are completely unrolled Installation of the external he...

Страница 7: ...the device I stands for cooling mode II stands for ventilation mode Shutdown 1 Use the ON OFF switch 18 to switch the device off 2 Remove the mains plug from the mains socket 3 Disconnect all connecti...

Страница 8: ...heat exchanger for proper fit The device automatically performs a reset The warning message HIPS is displayed Check the connection lines leading to the external heat exchanger for proper fit Check th...

Страница 9: ...Replace air filter x Check for damage x Check attachment screws x x Test run x Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign o...

Страница 10: ...the inside of the device 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 If you see a thick layer of dust have the inside of the device cleaned by a specialist compan...

Страница 11: ...edges of the air filter must not be rounded or misshaped Before reinserting the air filter ensure that it is dry and is not damaged Observe the maintenance intervals to replace the air filter in due...

Страница 12: ...waste but must be disposed of professionally in accordance with Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment WEEE...

Страница 13: ...aintenance etc or unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version Air Conditioner Series PT Year of manufacture as of June 2014 App...

Страница 14: ......

Страница 15: ......

Страница 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: