background image

5

Operating Manual – Air Conditioner PT 6500 S

EN

Transport

Prior to every transport observe the following instructions:
1. Switch off the device.

2. Remove the mains plug from the mains socket.

3. Disconnect all connections between basic device and

external heat exchanger.

4. Empty the tank.

Storage

Empty the tank and dispose of the water / glycol mixture properly.
When the device is not being used, observe the following storage
conditions:

• dry,

• protected from dust and direct sunlight,

• with a plastic cover to protect it from invasive dust, if

necessary.

• Avoid open doors and windows.

Installation of the basic device

When positioning the device, observe the minimum distance from
walls or other objects as described in the chapter Technical data.

• Set the device up in a level, upright and stable position.

• Do not create tripping hazards when laying the power cable

or other lines.

• Make sure that no curtains or other objects interfere with the

air flow.

• Ensure that extension cords are completely unrolled.

Installation of the external heat exchanger

Please note, that to the front the external heat exchanger requires
a minimum distance of 3 m to the wall or other objects.
To the rear a spacer ensures the correct distance.

Connecting basic device and external heat exchanger

Wear safety glasses

For start-up, maintenance and fault clearance always
wear safety glasses.

Wear protective gloves

For start-up, maintenance and fault clearance always
wear protective gloves.

1. Connect the condensation hose (3) to the connection (11)

provided at the external heat exchanger.

2. Connect the external heat exchanger with the power

cable (13, 8).

3. Connect the lines (red for the cooling water transport to the

external heat exchanger (4, 9), blue for the cooling water
transport from the external heat exchanger (12, 10)).

Transport and storage

Operation

C

C

A

B

D

14

3

13

12

4

8

10

9

11

Содержание PT 6500 S

Страница 1: ...OPERATING MANUAL AIR CONDITIONER EN PT 6500 S TRT BA PT6500S TC 003 EN...

Страница 2: ...uplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the...

Страница 3: ...erant cools down the air coming from the room and in doing so absorbs the heat The thusly cooled air is introduced to the room where the device is positioned via the fan Accumulating condensate is dis...

Страница 4: ...ensions external heat exchanger height x width x depth 1200 mm x 815 mm x 360 mm 510 mm x 650 mm x 320 mm Maximum distance between basic device and external heat exchanger 30 m Minimum distance of ext...

Страница 5: ...the basic device outdoors Do not place any objects e g wet clothing on the device for drying Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications...

Страница 6: ...s when laying the power cable or other lines Make sure that no curtains or other objects interfere with the air flow Ensure that extension cords are completely unrolled Installation of the external he...

Страница 7: ...the device I stands for cooling mode II stands for ventilation mode Shutdown 1 Use the ON OFF switch 18 to switch the device off 2 Remove the mains plug from the mains socket 3 Disconnect all connecti...

Страница 8: ...heat exchanger for proper fit The device automatically performs a reset The warning message HIPS is displayed Check the connection lines leading to the external heat exchanger for proper fit Check th...

Страница 9: ...Replace air filter x Check for damage x Check attachment screws x x Test run x Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign o...

Страница 10: ...the inside of the device 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 If you see a thick layer of dust have the inside of the device cleaned by a specialist compan...

Страница 11: ...edges of the air filter must not be rounded or misshaped Before reinserting the air filter ensure that it is dry and is not damaged Observe the maintenance intervals to replace the air filter in due...

Страница 12: ...waste but must be disposed of professionally in accordance with Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment WEEE...

Страница 13: ...aintenance etc or unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version Air Conditioner Series PT Year of manufacture as of June 2014 App...