Operating manual – local air conditioner PAC 2010 S
4. Reinsert the air filters into the device.
Sleeping
Timer
Mode
Speed
POW
ER
Sleeping Timer
Fan Cooling
Spee
d
Dehumidifying
Automatic
°F °
C H
Condensate discharge (manual draining)
In
cooling
and
dehumidification
mode condensate is formed,
which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the
housing. The condensate ought to be drained regularly.
If too much condensate accumulates, the device switches off
and indicates this via the
E4
error code on the segment
display (11).
1. Carefully transport or wheel the device to a suitable location
for discharging the condensate (e.g. a drain) or position a
suitable collection container under the condensate outlet.
Sleeping
Timer
Mode
Speed
PO
WE
R
Sleeping Timer
Fan Cooling
Sp
eed
Dehum
idifying
Auto
mat
ic
°F
°C
H
2. Remove the rubber stopper from the condensate outlet.
Sleeping Timer
Mode
Speed
POW
ER
Sleeping Timer
Fan Cooling
Speed
Dehu
midify
ing
Aut
omat
ic
°F °C H
3. Drain the condensate.
4. Reattach the rubber stopper to the condensate outlet.
Ensure the tight fit of the rubber stopper, for otherwise
there might be uncontrolled water leakage.
Sleeping Timer
Mode
Speed
POW
ER
Sleeping Timer
Fan Cooling
Speed
Dehu
midify
ing
Aut
omat
ic
°F °C H
ð
The
E4
error code on the segment display (11) will
disappear as soon as the condensate has been drained.
Refrigerant circuit
•
The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.