EN
10
Operating manual – local air conditioner PAC 2010 S
Switching the device on
1. Allow the device to rest for a time.
2. Once you have completely installed the device as described
in the Start-up chapter, you can switch it on.
3. Press the
POWER
button (13).
ð
The device starts in
automatic operation
mode.
ð
The
POWER
LED (14) is illuminated.
4. Select the desired operating mode.
The device switches off automatically when the condensation
tank is full.
E4
is displayed in the segment display (11).
Setting the operating mode
Cooling
In
cooling
mode the room will be cooled down to the desired
target temperature.
1. Press the
Mode
button (16) until the
Cooling mode
LED (12)
is illuminated.
ð
The current room temperature is indicated on the
segment display (11).
2. Repeatedly press the
Increase value
(18) or
Decrease value
button (17) to select the desired target temperature. The
temperature can be adjusted in increments of 1 °C in a
range between 15 °C and 31 °C.
ð
The desired target temperature flashes on the segment
display (11) for approx. 5 s. Then the segment
display (11) changes back to the current room
temperature.
3. Press the
Speed
button (15) to set the desired fan stage.
ð
The
Speed
LED (10) for the selected fan stage will be
illuminated.
ð
The
Cooling
LED (12) will be illuminated to indicate
cooling mode
.
Dehumidification
Info
Remove the exhaust air hose during
dehumidification
,
otherwise the performance will be insufficient.
In
dehumidification
mode the humidity level in the room is
reduced.
The temperature cannot be adjusted and the fan runs at speed
level 1.
1. Press the
Mode
button (16) until the operating mode LED for
Dehumidifying
(12) is illuminated.
ð
The
Speed
LED (10) for fan stage 1 will be illuminated.
ð
The
Dehumidifying
LED (12) will be illuminated to
indicate
dehumidification mode
.
Info
If the device is operated in a very humid environment,
the accumulating condensate must be discharged at
regular intervals (see chapter Condensate discharge).
Connecting the condensation drain hose
If you use the device for a extended period of time or you don't
want to empty the tank all the time, you can connect a
condensation drain hose to the hose connection.
ü
The device is switched off.
ü
The device is disconnected from the mains.
1. Carefully transport or wheel the device to a suitable location
for discharging the condensate (e.g. a drain) or position a
suitable collection container under the condensate outlet.
2. Remove the rubber stopper from the condensate outlet (7).
Sleeping Timer
Mode
Speed
POW
ER
Sleeping Timer
Fan Cooling
Speed
Dehu
midify
ing
Aut
omat
ic
°F °C H
3. Keep the rubber stopper for later use.
4. Connect the condensation drain hose to the condensate
outlet (7).