background image

EN

13

radiant heater IR 2000 C / IRS 2010

Technical annex

Technical data

Parameter

Value

Model

IR 2000 C

IRS 2010

Heating capacity

2000 W

2000 W

Mains connection 220-240V ~

50/60 Hz

220-240V ~
50/60 Hz

Plug type

CEE 7/7

CEE 7/7

Cable length

180 cm

180 cm

Protection class

IP55

IP55

Weight

5 kg

18 kg

Dimensions 
(length x width x
height)

380 x 670 x 100 mm 360 x 670 x

2200 mm

Minimum distance
to walls or other
objects

A: top:

B: bottom:

C: side:

D: front:

30 cm
180 cm
100 cm
100 cm

30 cm
180 cm
100 cm
100 cm

Remote control
batteries

AAA/1.5V

AAA/1.5V

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. You can also find out about other return options
that apply for many EU countries on the website 
https://hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment
authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

In the European Union, batteries and accumulators must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6 September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Содержание IR 2000 C

Страница 1: ...TRT BA IR2000C IRS2010 TC211001TTRT08 001 EN IR 2000 C IRS 2010 EN OPERATING MANUAL RADIANT HEATER ...

Страница 2: ...you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity via the following link IR 2000 C https hub trotec com id 45862 IRS 2010 https hub trotec com id 45863 Safety Read this manual carefully before start...

Страница 3: ...o the specifications in the Technical annex Insert the mains plug into a properly fused mains socket Observe the device s power input cable length and intended use when selecting extensions to the power cable Completely unroll extension cables Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains ...

Страница 4: ...st not be covered Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Warning ...

Страница 5: ...upright position is changed in any other manner The tilt protection switches the device off when it is inclined out of its vertical position The device can again be used as usual only a few seconds after placing it back in vertical position and on solid ground Information about the device Device description The device is used to quickly generate instant heat The device is based on the functional p...

Страница 6: ...e pulling the power cable out of the mains socket Do not use the power cable to drag the device Allow the device to cool down sufficiently Storage Before storing the device proceed as follows Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down sufficiently When the device is not being used observe the following storage conditions dry and pro...

Страница 7: ...ectrician Warning Risk of fire due to improper installation There is a risk of fire if the required minimum distances are not observed Observe the Installation section in the Assembly and start up chapter and the technical data in the Technical annex chapter Warning The device must not be placed directly below a socket as the electrical cables may be hit when the device is being mounted This may c...

Страница 8: ...own by tightening them 6 5 3 Connect the plug of the power cable to the socket of the radiant heater ð Fix the plug of the power cable 4 Guide the mains cable from above through the mounted rod and foot 5 Place the radiant heater on the tube and fix it using 2 screws 6 Adjust the radiant heater to the desired height and fix the telescopic rod with twist lock 5 7 Carefully tilt the device ...

Страница 9: ... and screw down the three fixation plates in place as indicated 4 Check the foot for tight fit Installation When installing the device observe the minimum distances from walls and other objects as described in the Technical data chapter A B C C D D IR 2000 C IRS 2010 B D C C D Never install the device in a way that it radiates directly onto walls or other objects Observe the minimum distances from...

Страница 10: ...lar objects in the immediate vicinity Prior to initial start up insert batteries in the remote control Connecting the power cable Insert the mains plug into a properly fused mains socket Operation Operating elements IR 2000 C 8 9 1 IRS 2010 1 8 9 Remote control 10 12 11 No Designation Meaning 8 Segment display Heating level indication L1 heating capacity 1000 W L2 heating capacity 2000 W 9 Power L...

Страница 11: ...ion 0 Allow the device to cool down completely Hold onto the mains plug while pulling the power cable out of the mains socket Clean the device according to the Maintenance chapter Store the device according to the Transport and storage chapter Errors and faults Warning of electrical voltage Tasks which require the device to be opened must only be carried out by authorised specialist companies or b...

Страница 12: ... the customer service If necessary bring the device to an authorised specialist electrical company or to Trotec for repair Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down compl...

Страница 13: ...equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separate collection of waste electrical and...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...