radiant heater IR 2000 C / IRS 2010

The device does not respond to the infrared remote control:

Check whether the distance between remote control and
device is too large and reduce it if necessary.

Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.

Check the charging status of the batteries and change
them if required.

If the batteries have just been changed, check them for
correct polarity.

The LED elements do not work:

Check whether the power cable is plugged in correctly.

Check whether the unit is switched on.

Check all LED elements for damages.

The LED elements may be defective. Contact the Trotec
customer service.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

The device still does not operate correctly after these
checks:

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.

Cleaning the device

Warning of electrical voltage

Never immerse the device in water!

Warning of hot surface

Do not touch the reflector or the heating rods with bare
hands.

Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Dirt on the heating rods should be removed with a long brush
with soft bristles.

Содержание IR 2000 C

Страница 1: ...TRT BA IR2000C IRS2010 TC211001TTRT08 001 EN IR 2000 C IRS 2010 EN OPERATING MANUAL RADIANT HEATER ...

Страница 2: ...you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity via the following link IR 2000 C https hub trotec com id 45862 IRS 2010 https hub trotec com id 45863 Safety Read this manual carefully before start...

Страница 3: ...o the specifications in the Technical annex Insert the mains plug into a properly fused mains socket Observe the device s power input cable length and intended use when selecting extensions to the power cable Completely unroll extension cables Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains ...

Страница 4: ...st not be covered Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Warning ...

Страница 5: ...upright position is changed in any other manner The tilt protection switches the device off when it is inclined out of its vertical position The device can again be used as usual only a few seconds after placing it back in vertical position and on solid ground Information about the device Device description The device is used to quickly generate instant heat The device is based on the functional p...

Страница 6: ...e pulling the power cable out of the mains socket Do not use the power cable to drag the device Allow the device to cool down sufficiently Storage Before storing the device proceed as follows Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down sufficiently When the device is not being used observe the following storage conditions dry and pro...

Страница 7: ...ectrician Warning Risk of fire due to improper installation There is a risk of fire if the required minimum distances are not observed Observe the Installation section in the Assembly and start up chapter and the technical data in the Technical annex chapter Warning The device must not be placed directly below a socket as the electrical cables may be hit when the device is being mounted This may c...

Страница 8: ...own by tightening them 6 5 3 Connect the plug of the power cable to the socket of the radiant heater ð Fix the plug of the power cable 4 Guide the mains cable from above through the mounted rod and foot 5 Place the radiant heater on the tube and fix it using 2 screws 6 Adjust the radiant heater to the desired height and fix the telescopic rod with twist lock 5 7 Carefully tilt the device ...

Страница 9: ... and screw down the three fixation plates in place as indicated 4 Check the foot for tight fit Installation When installing the device observe the minimum distances from walls and other objects as described in the Technical data chapter A B C C D D IR 2000 C IRS 2010 B D C C D Never install the device in a way that it radiates directly onto walls or other objects Observe the minimum distances from...

Страница 10: ...lar objects in the immediate vicinity Prior to initial start up insert batteries in the remote control Connecting the power cable Insert the mains plug into a properly fused mains socket Operation Operating elements IR 2000 C 8 9 1 IRS 2010 1 8 9 Remote control 10 12 11 No Designation Meaning 8 Segment display Heating level indication L1 heating capacity 1000 W L2 heating capacity 2000 W 9 Power L...

Страница 11: ...ion 0 Allow the device to cool down completely Hold onto the mains plug while pulling the power cable out of the mains socket Clean the device according to the Maintenance chapter Store the device according to the Transport and storage chapter Errors and faults Warning of electrical voltage Tasks which require the device to be opened must only be carried out by authorised specialist companies or b...

Страница 12: ... the customer service If necessary bring the device to an authorised specialist electrical company or to Trotec for repair Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down compl...

Страница 13: ...equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separate collection of waste electrical and...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: