DL200X operating manual for external sensors

13

EN

11. Technical data

DL200X data logger for external sensors

Voltage input 
0 - 1 V

Measuring range

0 … 1 V

Accuracy

±200 µV ± 0.1 % of measured value

Resolution

< 500 µV

Voltage
 measurement

Measuring range

2-cable operation: 4 … 20 mA, 3-cable operation: 0 … 20 mA

Accuracy

± 4 µA ± 0.1 % of measured value

Resolution

< 5 µA

Total load

approx. 50 Ω

Thermal element K

Measuring range

-200 °C … 1,200 °C

Accuracy

± 1 °C ± 0.5 % of the measured value at -200 °C … 0 °C, 

± 1 °C ± 0.2 % of the measured value at 0 °C … 1,200 °C 

Resolution

< 0.2 °C

Thermal element J

Measuring range

-200 °C … 1,200 °C

Accuracy

± 1 °C ± 0.5 % of the measured value at -200 °C … 0 °C, 

± 1 °C ± 0.2 % of the measured value at 0 °C … 1,200 °C 

Resolution

< 0.2 °C

Thermal element S

Measuring range

-50 °C … 1,700 °C

Accuracy

± 1 °C ± 0.5 % of the measured value at -50 °C … 0 °C, 

± 1 °C ± 0.2 % of the measured value at 0 °C … 1,700 °C 

Resolution

< 0.2 °C

Pt100

Measuring range

-200 °C … 500 °C

Accuracy

± 0.2 °C ± 0.1 % of the measured value

Resolution

< 0.02 °C

Memory 
organisation

Sensing interval

10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h

Saving interval

1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h

Data storage

16 MB, approx. 3,200,000 measured values

Data recording

up to 20 simultaneous measuring channels

Configuration and 
dimensions

LCD display

W 90 x H 64 mm

Housing

Plastic

Dimensions

L 180 x W 32 x H 78 mm

Weight

approx. 250 g

Interfaces

USB, LAN, RS485 (Sensor BUS)

Power supply

internal

4 x LR6 AA batteries, battery life > 1 year 

(depending on connected sensor and configuration)

external

USB, LAN (PoE configuration), 

terminals for external power supply to supply the sensor 

Permissible 
operating ambient
conditions

Air temperature

-20 °C to +50 °C

Relative humidity

0 to 95 % RH, < 20 g / m³ (non-condensing)

Height

10,000 m above sea level

Scope of supply

Standard

Measuring device, CD-ROM with SmartGraph3 PC software for representing the evaluation 

of measured values graphically and numerically and operating manual, 

USB connection cable, batteries

Optional

Measuring device in PoE configuration, TFF sensors

Содержание DL200X

Страница 1: ...DL200X EN TRT BA DL200X WM 03 EN OPERATING MANUAL DATA LOGGER FOR EXTERNAL SENSORS...

Страница 2: ...ss of the results presented is excluded from any liability or guarantee Liability for damages which have been caused by utilising the presented measured results is strictly excluded 2 Intended use The...

Страница 3: ...ording Display for inactive measured value recording Display for date Display for time Mode selection button Data logger for connecting to external sensors 3 Equipment 5 pin round connector M12 for co...

Страница 4: ...left and the display returns back to the original mode without making changes This function is only available if a BUS sensor has already been registered M61 M81 An 0 M1 M2 M3 M4 M51 M52 M53 M6x M81 A...

Страница 5: ...essary that UDP broadcasts are allowed through the network b Note Based on their concept UDP broadcasts do not operate through a router NAT but instead only within its own network If the data logger i...

Страница 6: ...e BUS sensor to the 5 pin round connector of the data logger see chapter 3 The sensor is supplied with current via the plug By optionally using up to three Y distributors a maxi mum of four digital BU...

Страница 7: ...el 2 has pins 2 4 6 8 and 10 see chapter 3 Both of the input channels support the sensor configurations listed in the following subchapters Example display Registration function M61 selection for regi...

Страница 8: ...r the first input channel Alternatively navigate to the configuration mode M81 AN1 to configure the specification of a sensor for the second input channel The option for configuring the first analogue...

Страница 9: ...1 Further detailed information about configuration of the processing channels in the software is provided in the software manual which you can open by us ing the help function of the SmartGraph softw...

Страница 10: ...on 0 20 mA Current mA cur min max mid Pt100 temperature measurement in 3 cable operation Temperature C cur min max mid Pt100 temperature measurement in 3 cable operation Temperature F cur min max mid...

Страница 11: ...display Additionally a hysteresis can be set by which the measured value must return to the valid range to switch off the alarm Example display for an alarm result of the measuring channel shown in th...

Страница 12: ...itioning for mobile use For mobile measured value recording the data logger can be positioned at any site Observe the permissible ambient conditions for operation see technical data Due to its compact...

Страница 13: ...C Accuracy 0 2 C 0 1 of the measured value Resolution 0 02 C Memory organisation Sensing interval 10 30 s 1 10 12 15 30 min 1 3 6 12 24 h Saving interval 1 10 12 15 30 min 1 3 6 12 24 h Data storage 1...

Страница 14: ...gative polarity approx 0 024 V 0x53 CHANNEL_UNDERRANGE Limit range 0 024 V 0 000 V Displayed 0 000V Normal operation mode 0 000 V 1 000 V Limit range 1 000 V 1 024 V Displayed 1 000V Overvoltage appro...

Страница 15: ...Trotec GmbH Grebbener Stra e 7 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: