Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+
3. Remove the housing.
4. Check whether the float in the container floats. If required,
fill a little water into the condensation tray. If the float is
stuck and does not float, it could help to lightly tap the side
of the container.
5. Check whether water has accumulated in the condensate
collection container or the condensation tray.
6. If so, clean the drain hoses.
7. Put the housing back on the device.
8. Fasten the housing to the device.
9. Plug the power cable back into the mains socket.
If the alarm signal continues despite these measures, please
contact Trotec.
The device gets very warm, is loud or loses power:
•
Check the air filter for dirt. Remove external dirt.
•
Check the inside of the device for dirt. If necessary, clean
the interior of the device using compressed air.
Your device still does not operate correctly after these
checks?