condenser dryer DH 160 / TTK 1600
Operation
Operating elements
R.H.
9
10
11
12 13
14
15
16
17
18
19
20
21
22
23
24
25
26
No. Designation
Meaning
9
POWER
LED
Illuminated during standby and
ongoing operation
10
ON
LED
Illuminated during ongoing operation
11
ALARM
LED
Illuminated in the event of an error
message
In addition, the error code is displayed
on the segment display, see chapter
Errors and faults
12 Segment display
Indication of the current room humidity
level
Indication of the desired room humidity
level
Indication of the number of operating
hours
Indication of the error code, see
chapter Errors and faults
13
RUN
LED
Flashes when the compressor
switches on
14
PUMP
LED
Illuminated in the event of a condenser
malfunction
15
REMOTE
CONTROL
LED
Illuminated during operation with an
external hygrostat
16
R.C.
button
For establishing a connection to the
external hygrostat (option)
17
HOURS
button
Number of operating hours is
displayed
18
Increase value
button
For increasing the desired relative
humidity level (30 % to 80 %)
For deactivating continuous operation
No. Designation
Meaning
19 On/off switch
For switching the device on and off
20
R.C.
connection
Connection to the external hygrostat
21
LPS
LED
Illuminated in the event of a fault in the
refrigerant circuit
22
PUMP
button
For switching the condensate pump on
and off
23
OFF
position
Device switched off
24
ON
position
Device switched on or in standby
mode
25
Decrease value
button
For reducing the desired relative
humidity level (30 % to 80 %)
For activating continuous operation
26
ON/OFF
button
For switching dehumidification mode
on and off
Switching the device on
1. Once you have completely installed the device as
described in the Start-up chapter, you can switch it on.
2. Turn the on / off switch (19) to the
ON
position (24).
ð
In device will switch to standby mode.
3. Press the
ON/OFF
button (26).
ð
The device starts to dehumidify.
Setting the desired relative room humidity
The desired relative room humidity can be preselected at any
time.
1. Press the
increase value
(18) or
decrease value
button (25)
to set the desired relative room humidity. Setting is
possible in the range between 30 % and 80 %.
ð
The segment display (12) indicates the value for
approx. 4 s.
The device keeps running until reaching the desired relative
room humidity. Once the desired relative room humidity is
exceeded, the compressor and fan switch back on.
Continuous operation
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity.
ü
The desired relative room humidity is set to 30 %.
1. Press the
decrease value
button (25) to activate continuous
operation.
ð
When continuous operation is activated,
Cont.
is shown
on the segment display (12).
2. Press the
increase value
button (18) to deactivate
continuous operation.
ð
The desired humidity value is displayed.