16
EN
condenser dryer DH 160 / TTK 1600
3. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.
4. Allow the filter to dry completely. Do not insert a wet filter
into the device!
5. Reinsert the air filter into the device.
6. Reattach the air inlet cover (4) to the device.
Cleaning the condensate pump
Perform this activity at least once a year.
1. Loosen the three attachment screws at the service panel
with 1/4 turn.
2. Remove the service panel from the device.
3. Remove the hose lines from the pump connections.
4. Clean the hose lines and connections at the pump and
remove any dirt.
5. Reconnect the hose lines and check all hose connections.
6. Reattach the service panel to the device by turning the
attachment screws 1/4 turn.