Page: 43
ADVANTAGE ENGINEERING, INC.
525 East Stop 18 Road Greenwood, Indiana 46142
317-887-0729 Fax: 317-881-1277 Service Fax: 317-885-8683
web site: www.AdvantageEngineering.com
Service Department email: [email protected]
TROOPER : Negative Pressure System
6.21 TR-350, TR-400, TR-500 3Ø AC LADDER DIAGRAM
MTR1
OL1
OL1
OL1
T1
T2
T3
MS1
MS1
MS1
3
4
5
L1
L2
L3
PM1
PHASE
MONITOR
H1
H4
H3
H2
T1
X1
X1
120V
POWER
PHASE
S1
9
(8)
(1)
4
PS1
6
6
(96)
(95)
11
4
4
5
16
FU1
1A
PM1
OL1
LOW PRESSURE
14
16
FLOAT
PS1
LOW PRESSURE
R
LT1
LOW PRESSURE
4
13
13
15
13
R
5
12
MS1
LTS1
POWER ON
SOL1
L1
L2
L3
240V
3PH
60HZ