TROOPER : Negative Pressure System
NOTE: Pump parts for each model listed separately.
PLUMBING
Strainer
P STN-1
To & from mold gauges
P GA30-60
Supply & return gauges
P GA0-100
Regulator
P REG-1 WATTS
Air vent
P VENT-L2/L3
ELECTRICAL
Low pressure switch
E SW L PRS BD
High pressure switch
E SW H PRS L1
On/off switch
E SW-ROCKER
Indicator lights
E P-LGT RED3000
Motor starter relay
E CNTR-AEG
Transformer
E TRANS-V050
Solenoid Valve
E SLND1/4
Float switch (see appendix “float switch assembly”)
Overload (see appendix “changing voltage” for part number)
Phase monitor (see appendix “changing voltage” for part number)
6.10 REPLACEMENT PARTS
8 PSI.
5.
Boiling water, steam in pump. Stator often fails first. Refer
to appendix “Boiling points of water under vacuum”.
6.
Abrasive particles in system water, especially when unit is
run without supply strainer screen. Also damages rotor.
7.
Improper replacement procedures.
8.
Stator stop has been removed.