6 TX3706-UM-EN-02
1.4 Technical Information
Housing material:
Stainless Steel : ANC4B
Aluminium Alloy : LM
25
TF with hard anodised protection
Cable entry on free
plug and receptacle:
Choice of threaded cable entry sizes for standard Ex d cable glands
M20 and M25
Mounting of fixed
receptacle:
•
M20 onto Ex d or Ex e housing
•
M25 onto Ex d or Ex e housing
Connections of fixed
receptacle:
1.5 mm
2
x 1m / 2m / 3m (L)
2.5 mm
2
x 1m / 2m / 3m (L)
Mating cycles:
100,000 with no load connected
(Limited to 200 for live disconnect)
Security Coding:
5 selectable coding positions - A, B, C, D, E
Ingress protection:
IP66
Temperature limits:
-50 °C to +60 °C
Weight:
Free Plug
Free Receptacle
Fixed Receptacle
Stainless Steel Aluminium
0.5kg 0.2kg
0.43kg 0.17kg
0.4kg 0.15kg
Conformity:
EN 61984: 2009 - Safety Requirements
EN 60664: 2007 - Insulation Co-ordination
EN60079-0: 2012+A11:2013 - General Requirements
EN60079-1: 2014 - Flame-proof Enclosures
EN60079-7: 2015 -Explosive atmospheres. Equipment protection by
increased safety “e”
EN60079-31: 2014 - Equipment Dust Ignition Protection
by Enclosure “t”
www.trolex.com