4.2.3 Live engagement
ENGAGE or SEPARATE the connector with live power in the hazardous area, is permitted for
short periods to allow maintenance or change-out of apparatus.
Power must originate from the SOCKET ONLY.
Engage
Ex d Protection
Break
Ex d Protection
Separate
IP30 on Socket
Checkpoint
Maximum Voltage . 4 way 250 V ac/dc
Maximum Voltage .10 way 80 V ac
Maximum breaking current (per contact) 1 A
Power factor Between 0.6 and 1.0
IP65 Only
Ex d + IP66
Fit the rubber ingress protection cap
during temporary separation to exclude
dust and moisture.
Fit an Ex protection cap if the connection
is to remain separated after the permitted
maintenance period.
→
→