16 TX3706-UM-EN-02
3.4.2
Ex d bush mounting
TX 3706.3...20
TX 3706.3...25
Ex e
Ex d
1. Screw the locking ring all the way home.
2. Screw the Receptacle all the way into the mounting bush on the enclosure. This must be
a minimum of five threads engaged on an Ex d enclosure.
3. Use a half-spanner to apply counter-clockwise locking force to the locking ring.
A locking ring enables the Receptacle to be radially positioned to suit user preference and
incorporates ingress seals to IP66 standards.
•
Position the Receptacle to concur with any radial position of the corresponding free plug.
•
Align Receptacles for best visual appearance
•
Locks against the effect of rotational forces which may occur from the connecting cable.
www.trolex.com