9

1.

 With the meter off , insert a new test strip 

into the test port.

2.

Use the                     buttons to switch between 

the fl ashing cat and dog symbols.

3.

 Press        to save the correct animal symbol.

4.

 The fl ashing drop symbol will appear, 

indicating that the meter is ready for 

testing.

5.

 When the meter is turned off  the animal 

selection is saved in memory.

Note:

 Follow the steps above to change the 

animal type.

Setting/Changing Animal Type

Set the animal type (         dog or          cat) when you use the meter for the fi rst time.
If testing more than one animal, make sure the correct animal type is displayed before you 

begin testing.

Important!

 Applying a sample drop (blood or control solution) without fi rst selecting the 

animal type will give an error message (see 

Error Messages

 section).

PetMeterOwnersBooklet_XE4HTK03r1.indd   9

7/27/20   14:45

Содержание Healthy Tracks for Pets Test Buddy

Страница 1: ...SPECIALLY FOR DOGS CATS BLOOD GLUCOSE SYSTEM Instructions for Use Instructions for Use Forinvitrodiagnosticuseonly Forusewithfresh capillaryorfresh venous wholebloodsamplestakenfromadogorcat NOT FOR H...

Страница 2: ...andingBloodGlucoseTestResults 14 LoandHiResultsDisplay 14 MeterMemory 15 ViewingResults 15 ViewingAverages 15 QualityControlTesting 16 AutomaticSelf Test 16 ControlSolutionTest 16 MeterCleaningandDisi...

Страница 3: ...TAbloodcollectiontube Ashortdrawinto anEDTAcollectiontubethatislessthanhalfofthedesignatedfillvolumemaycause falselylowresults TestBuddyPet MonitoringBloodGlucoseMetercanbeusedonmultipledogsandcats Te...

Страница 4: ...emonitoringbloodglucose Donotuseforthescreeningordiagnosisofdiabetes Bloodglucosevaluesareaffectedbystress meals exercise health andmedications Severe dehydrationandexcessivewaterlossmaycauseinaccurat...

Страница 5: ...Removetheprotectiveplasticoverlayonthedisplayscreenbefore usingthemeterforthefirsttime StripReleaseButton Pushtoreleaseteststripaftertesting TestPort Insertteststriphere BackofMeter BatteryDoorUsesone...

Страница 6: ...tionDate ControlSolutionRanges Controlsolutionresultmustfallwithinthisrangefor thelevelyouareusing Note Thisisnotthetargetrangeforyourpet sbloodglucose Important ReadtheTestStripInstructionsforUsebefo...

Страница 7: ...d expirationdate EXP ortheopenbottleexpirationdatehaspassed whichevercomes first SeetheControlSolutionInstructionsforUseforinstructionsondeterminingtheopen bottleexpirationdate Care and Storage Storet...

Страница 8: ...forPM appearsnexttothetime Press tosave Themeterbeepsandtheminutesflash SetMinutes Press ifcorrector tochange Press tosave Themeterbeepsandthemonthand dayappearinthedisplay 3 Set Date SetMonth Themont...

Страница 9: ...Event Tags On or Off EventTagsareusedtomarkatestresulttakenduring aspecificevent ThemetercomeswiththeEventTag featureturnedon Press toturnEventTagsonoroff Setupiscomplete GotoStep6toexitsetup 6 Exit...

Страница 10: ...fftheanimal selectionissavedinmemory Note Followthestepsabovetochangethe animaltype Setting Changing AnimalType Settheanimaltype dogor cat whenyouusethemeterforthefirsttime Iftestingmorethanoneanimal...

Страница 11: ...etheMeterCleaningand DisinfectingandLancingDeviceCleaningandDisinfectingsections Blood GlucoseTesting Beforetesting Readallinstructionsforuseandgathertestingsupplies Makesuremeter teststrips andcontro...

Страница 12: ...tthedesiredlancingdepth Gently pullthearmingbarrelbackuntilyouhear aclick 4 Placelancingdevicetipfirmlyagainst thetestsiteandpressthetriggerbutton Removelancingdeviceandsetaside Allow blooddroptoform...

Страница 13: ...hemeterdoesnotturnonoranerrormessage appears seeTroubleshootingsection 3 Thedisplayshowsthetime animalsymbol andblinkingdrop Makesurethattheanimal symbolmatchestheanimalyouaretesting seeSetting Changi...

Страница 14: ...ingtheteststripbeforethe resultdisplayscancelsthetest Anerror messageappears andtheresultisnotstored inmemory Retestwithanewteststripand donotremovebeforetheresultisdisplayed TheEventTagsymbolswillfla...

Страница 15: ...eepingresultswithinthetargetrangehelps sloworstopcomplicationsofdiabetes NEVERchangeyourpet streatmentplanwithouttheadviceofaveterinarian Lo and Hi Results Display Important Themeterreadsbloodglucosel...

Страница 16: ...llforwardsthroughresults Press toscroll backwards Testsmarkedwithaneventtagshowtheeventtagsymbolinthe display Examplesonly Exampleonly Exampleonly Withmeteroffpressandrelease Thedisplayscrollsthrough...

Страница 17: ...sforUseprovidedwiththeTestBuddyControlSolutionbottlebeforeusing Performcontroltests topracticebeforeusingthesystemtotestbloodglucoseforthefirsttimetoensure testingtechniqueisgood afteropeninganewvialo...

Страница 18: ...aftertheprintedexpiration date EXP ortheopenvialexpirationdate haspassed whichevercomesfirst seethe TestStripInstructionsforUseforinstructions ondeterminingtheopenvialexpirationdate Examplesonly May 8...

Страница 19: ...opoftheteststrip Wait forthecontrolsolutiontobedrawnintotheteststrip Holdtheteststriptothecontrolsolutiondropuntilthe meterbeepsanddashesmoveacrossthedisplay This meansthemeteristesting Removethetests...

Страница 20: ...intoasuitablewastecontainer LOT R 758 EXP 2023 10 31 1 31 61 mg dL 2 87 117 mg dL 3 254 344 mg dL X3HTK04 Rev 1 T MONITORING OOD GLUCOSE TEST STRIPS 0 Test Strips ufacturedby TrividiaHealth Inc auderd...

Страница 21: ...eananddisinfectthemeteratleastonceaweek Themetermaybecleanedand disinfectedonceaweekforupto5years UseonlyPDISuperSani Cloth Wipes EPAReg No 9480 4 Otherdisinfectantshave notbeentestedandmaydamagetheme...

Страница 22: ...usedwipes 4 Letmeterairdrythoroughlybeforeusingtotest 5 Washhandsthoroughlywhenfinished 6 PerformanAutomaticSelf Testtocheckthatthemeterisworkingproperly see QualityControlTestingsection To Disinfect...

Страница 23: ...arreldoesnotclickwhengentlypulledback To Clean the Lancing Device 1 Washhandsthoroughlywithsoapandwater 2 Thoroughlywipetheentireoutsidesurfaceofthelancingdevicewithone SuperSani Clothbywipingincircle...

Страница 24: ...etabonthebatterydoor 2 Holdthemeterinonehandwiththebatterydoorfacing downoverthepalmofyourotherhand Thebatteryfalls out Disposeofbatteryaccordingtoyourlocalwaste disposalregulations 3 InsertanewCR2032...

Страница 25: ...cingup Metererror ContactCustomerCareforassistance Meterdoesnotbeep andtestdoesnot startafterapplying sampledrop blood orcontrolsolution Sampledropis toosmall Repeattestwithnewteststripand largersampl...

Страница 26: ...eststrip or Teststripoutsideofvial toolong or Sampleplacedontopof teststrip Retestwithanewteststrip Makesurethe teststripsampletiptouchesthetopofthe sampledrop Iftheerrorreappears contactCustomer Care...

Страница 27: ...er Careforassistance Lowbattery Replacebattery Brokendisplay Donotusethemeter ContactCustomer Careforassistance Outofrangehighresult 600mg dL WARNING Retestwithanewteststrip IftheresultisstillLoorHi c...

Страница 28: ...shut off Aftertwominutesofnon use Weight 1 7oz Size 3 41 x2 16 x0 66 MemorySize 1000bloodglucoseandcontroltestresultswithdateandtime OperatingRange Meter TestStrips Usewithinspecifiedenvironmentalcond...

Страница 29: ...hemeter musthavetheBluetoothSMARTfeatureturnedonandyourmobiledevicemusthavethe TestBuddyAppinstalled Themetercanbepairedwithuptofour 4 mobiledevices Gotowww testbuddymeter comformoreinformationon TheT...

Страница 30: ...ocorrecttheinterferencebyoneormoreofthefollowingmeasures Movethemeterawayfromtheradioortelevisionantenna Movetheradioortelevisionantennaawayfromthemeter Ifyoucontinuetohaveproblems contactCustomerCare...

Страница 31: ...3 Donottakethemeterapart ThisactionwillvoidtheWarrantyandcausethemeterto displayfalseresults 4 ThedurationofanyimpliedWarranty includinganyimpliedWarrantyof merchantabilityorfitnessforaparticularpurp...

Страница 32: ...Inc The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Trividia Health Inc is under license Other trademarks and trade names are those...

Отзывы: