![Triumph Adler DP 773 Скачать руководство пользователя страница 86](http://html.mh-extra.com/html/triumph-adler/dp-773/dp-773_service-manual_1169915086.webp)
3PH
1-5-9
6. In case of copy sample (a):Turn the dial towards the direction of the arrow L.
In case of copy sample (b):Turn the dial towards the direction of the arrow R.
Amount of change per scale: Approx. 1.0 mm
Figure 1-5-15
7. Perform a test copy.
8. Repeat the steps above until the gap of line (2) of copy example shows the following reference values.
<Reference value> For single copying: The horizontal gap of line (2) should be within ±3.0 mm.
For duplex copying: The horizontal gap of line (2) should be within ±4.0 mm.
Figure 1-5-16
9. After the adjustment, install the inner cover which is removed in step 4.
10. Close the rear subcase cover.
11. Remove the original mat and refit it.
Dial
Scale
R
L
Copy sample (a)
Original
Copy sample (b)