background image

service policy

In the event of a complaint occurring, the 

following procedure should be followed:

1

 Telephone Customer Service on +44 (0) 24 

7637 2222

 

(+44 (0) 84 5762 6591 in Scotland 

and in Northern Ireland), having available the 

model number and power rating of the product, 

together with the date of purchase.

Triton Customer Service will be able to confirm 

whether the fault can be rectified by either the 

provision of a replacement part or a site visit from 

a qualified Triton service engineer.

3

 

If a service call is required the unit must be fully 

installed for the call to be booked and the date 

confirmed. In order to speed up your request, 

please have your postcode available when 

booking a service call.

4

 It is essential that you or an appointed 

representative (who must be a person of 18 years 

of age or more) is present during the service 

engineer's visit and receipt of purchase is shown.

5

 

A charge will be made in the event of an 

aborted service call by you but not by us, or 

where a call under the terms of guarantee has 

been booked and the failure is not product 

related (i.e. scaling and furring, incorrect water 

pressure, pressure relief device operation, 

electrical installation faults). 

6

 If the product is no longer covered by the 

guarantee, a charge will be made for the site visit 

and for any parts supplied.

7

 Service charges are based on the account being 

settled when work is complete, the engineer will 

then request payment for the invoice. If this is not 

made to the service engineer or settled within 

ten working days, an administration charge will 

be added.

Replacement parts policy

Availability:

 It is the policy of Triton to maintain 

availability of parts for the current range of 

products for supply after the guarantee has 

expired. Stocks of spare parts will be maintained 

for the duration of the product’s manufacture 

and for a period of five years thereafter.
In the event of a spare part not being available a 

substitute part will be supplied.

Payment: 

The following payment methods can be 

used to obtain spare parts:

1

 By post, pre-payment of pro forma invoice by 

cheque or money order.

2

 By telephone, quoting credit card (MasterCard 

or Visa) details.

3

 By website order, www.tritonshowers.co.uk

tRItoN stANdARd GuARANtee

Triton Plc guarantee this product against all 

mechanical and electrical defects arising from 

faulty workmanship or materials for a period of 

two years for domestic use only, from the date of 

purchase, provided that it has been installed by 

a competent person in full accordance with the 

fitting instructions.
Any part found to be defective during this 

guarantee period we undertake to repair or 

replace at our option without charge so long as 

it has been properly maintained and operated in 

accordance with the operating instructions, and 

has not been subject to misuse or damage.
This product must not be taken apart, modified 

or repaired except by a person authorised 

by Triton Plc. This guarantee applies only 

to products installed within the United 

Kingdom and does not apply to products used 

commercially. This guarantee does not affect 

your statutory rights.

What is not covered:

1

 

 Breakdown due to: 

a)

 use other than domestic 

use by you or your resident family;  

b)

 wilful act or neglect; 

c)

 any malfunction 

resulting from the incorrect use or quality of 

electricity, gas or water or incorrect setting of 

controls; 

d)

 faulty installation.

2

 

 Repair costs for damage caused by foreign 

objects or substances.

3

  Total loss of the product due to non-

availability of parts.

4

  Compensation for loss of use of the product or 

consequential loss of any kind.

5

 

 Call out charges where no fault has been 

found with the appliance.

6

 

 The cost of repair or replacement of pressure 

relief devices, showerheads, hoses, riser rails 

and/or wall brackets, isolating switches, electrical 

cable, fuses and/or circuit breakers or any other 

accessories installed at the same time.

7

 

 The cost of routine maintenance, adjustments, 

overhaul modifications or loss or damage arising 

therefrom, including the cost of repairing 

damage, breakdown, malfunction caused by 

corrosion, furring, pipe scaling, limescale, system 

debris or frost.

Triton Plc 

Triton Road 

Nuneaton 

Warwickshire  CV11 4NR

Customer service: 

%

 + (0)   

scottish and Northern Ireland 

Customer service: 

%

 

+ (0)   9

 trade Installer hotline: 

%

 + (0)   9 

Fax: + (0)   

www.tritonshowers.co.uk 

e mail: [email protected]

Содержание Zante

Страница 1: ...2180289H January 2006 Installers please note these instructions are to be left with the user Installation and operating instructions Zant electric shower...

Страница 2: ...Commissioning 13 Operating the shower 14 15 Operating functions 16 Fitting the riser rail 17 18 Fitting the hose and showerhead 18 Adjusting the showerhead 19 Cleaning the showerhead 20 Cleaning the f...

Страница 3: ...king the electrical connections 3 ELECTRICAL 3 1 The installation must comply with BS 7671 Requirements for electrical installations IEE wiring regulations building regulations or any particular regul...

Страница 4: ...mines the water temperature The slower the flow the hotter the water becomes the faster the flow the cooler the water b During winter the mains water supply will be cooler than in the summer so the fl...

Страница 5: ...tch flag assembly 8 Stabilising valve 9 Terminal block 10 Earth connection 11 Solenoid valve 12 Water inlet 13 Thermal cut out outlet 14 Pressure relief device PRD 15 Shower outlet Inside cover fig 2...

Страница 6: ...e connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circuit or cooker circuit 3 1 The electrical supply must be adequate for the l...

Страница 7: ...hose rooms must be protected by a 30mA RCD 9 To obtain full advantage of the power provided by the shower use the shortest cable route possible from the consumer unit to the shower 9 1 The current car...

Страница 8: ...it may not be possible to achieve optimum performance from the unit throughout the year During periods of high ambient temperatures it may be necessary to select a low power setting to achieve your d...

Страница 9: ...ck valve or similar must be fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed into the shower unit which complies with European...

Страница 10: ...ide entry is required the cover will have to be cut out Carefully remove the appropriate area by using a knife or junior hacksaw fig 10 If installing a feed pipe from the back or bottom the centre of...

Страница 11: ...plasterboard or a soft building block you must use suitable wall plugs and an appropriate drill Screw the bottom fixing screw into position leaving the base of the screw head protruding 6mm out from...

Страница 12: ...be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris to waste Procedure Turn off the water supply either at the mains stopvalve or th...

Страница 13: ...erheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through con...

Страница 14: ...the cold position fig 17 Offer the cover to the backplate unit Attached to the stop start switch inside the cover is a two wire lead The socket on the end of this lead must be connected to the plug t...

Страница 15: ...PRD to operate Turn on the mains water supply to the shower at the isolating stop valve and then turn on the electric supply to the shower at the isolating switch The power indicator will light Press...

Страница 16: ...required for the unit cannot be met due to low water pressure it will be necessary to operate the unit on this setting during the warmer months because of flow rate limitations entering the unit Full...

Страница 17: ...the flow of water through the shower and be indicated by the blue arrows To increase the shower temperature Turn the temperature control clockwise this will decrease the flow of water through the sho...

Страница 18: ...fficient and operating difficulties may be encountered A green indication shows that water pressure is sufficient for satisfactory operation of the shower Overheat cut out During normal operation if a...

Страница 19: ...racket end fig 26 Locate the second bracket on top of the rail Check the rail is vertical then mark the centre hole and of the other two holes Remove the bracket and rail Drill and plug the wall Fit t...

Страница 20: ...below the dish The collar is slightly tapered and should be fitted thinner section uppermost Make sure it locates firmly in the soap dish so it holds the dish at the required height on the rail Fitti...

Страница 21: ...c shower 19 ADJUSTING THE SHOWERHEAD Five showerhead patterns are available fig 36 Adjust the spray pattern by turning the bezel on the showerhead in either direction until the desired pattern is obta...

Страница 22: ...reaches a STOP Hold the cartridge firmly and continue to twist anti clockwise Having loosened the sprayplate it can be unscrewed and removed completely Clean the sprayplate with a suitable brush or pr...

Страница 23: ...nd removal of the compression fitting Also depending on the incoming pipework arrangements if there is not enough slack in the pipework it could mean the removal of the unit from the wall When cleanin...

Страница 24: ...00160 10 5kW 83000160 6 Stabiliser valve assembly 8 5kW 9 5kW 82600550 10 5kW 82600760 7 Solenoid valve assembly 83300450 Eaton 8 Outlet pipe assembly c w wires PRD 8 5kW 9 5kW 82200510 10 5kW 8500018...

Страница 25: ...3 SPARE PARTS Ref Description Part No 13 5 mode kwik kleen showerhead 22011270 14 Brackets pair 83306160 15 Riser rail 7042409 16 Showerhead holder 83306190 17 Soap dish 22008960 18 Flexible hose 2810...

Страница 26: ...blocked sprayplate in showerhead 2 2 1 Check if stop valves are fully open Check if blockage in inlet filter 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy power 3 1 1 See Water...

Страница 27: ...ter pressure resumes to normal 6 1 1 Clean or replace blocked sprayplate in showerhead and then fit new PRD 6 2 1 Check for free passage through hose Replace the hose if necessary and fit new PRD 6 3...

Страница 28: ...order 2 By telephone quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk Triton Standard Guarantee Triton Plc guarantee this product against all mechanical and e...

Страница 29: ...Pdf Supplied By http www plumbworld co uk...