background image

Zanté electric shower

1  

Shower 

inoperable, no water 
flow.
 

 
 

2

  Water too hot.

 

 

 
 

 Water 

temperature cycling 
hot/cool at intervals.

 Water too cool or 

cold.
 
 
 
 
 
 
 
 
 
 
 

1.1 

 Interrupted power 

supply. 
 
 

1.2

  Unit malfunction.

 

2.1

  Not enough water 

flowing through the 
shower.

2.2 

 Blockage in supply. 

2.3

  Increase in ambient 

water temperature.

3.1

  Heater cycling on 

outlet thermal cut-out.
 

4.1 

 Too much flow.

4.2

  Water pressure below 

minimum required (see 
rating label). 
 
 
 
 
 
 

4.3

  Reduction in ambient 

water temperature.

4.4

  Electrical malfunction 

or safety cut-out operated.

1.1.1 

 Blown fuse or circuit breaker. Check 

supply. Renew or reset fuse or circuit breaker. If it 
fails again, consult a qualified electrician. 

1.1.2 

 Power cut? Check other appliances and if 

necessary, contact local Electricity Supply Co.

1.2.1

  Have unit checked. Ring Customer 

Service.

2.1.1

  Increase flow rate via temperature control. 

2.1.2 

 Blocked showerhead — clean or replace 

blocked sprayplate in showerhead.

2.2.1

  Check if stop valves are fully open. Check 

if blockage in inlet filter.

2.3.1

  Readjust flow rate to give increased flow. 

2.3.2 

 Select ‘economy’ power.

3.1.1

  See

 'Water too hot' 

causes 2.1, 2.2 and 2.3 

and their appropriate action/cures. If it continues, 
contact Triton Customer Service.

4.1.1

  Reduce flow rate via temperature control.

4.2.1  

Is water supply mains or tank fed ? 

4.2.2

  If tank fed, replumb to mains water supply 

or see 4.2.4. 

4.2.3

  If mains fed, make sure that the mains 

stopvalve is fully open and there are no other 
restrictions in the supply while shower is in use, 
or see 4.2.4. 

4.2.4

 

 Fit pump to give minimum pressure 

(see rating label). Contact Customer Service for 
advice.

4.3.1 

 Readjust flow rate to give reduced flow. 

4.3.2  

Select ‘high’ power.

4.4.1

  Have unit checked by suitably qualified 

electrician or contact Triton Customer Service.

fAULT fINDING

ImpoRtANt: 

Switch oFF the electricity at the mains supply and remove the circuit fuse before 

removing the cover from the shower while attempting any fault finding inside the unit.

Problem/Symptom   Cause   

 

Action/Cure

Содержание Zante

Страница 1: ...2180289H January 2006 Installers please note these instructions are to be left with the user Installation and operating instructions Zant electric shower...

Страница 2: ...Commissioning 13 Operating the shower 14 15 Operating functions 16 Fitting the riser rail 17 18 Fitting the hose and showerhead 18 Adjusting the showerhead 19 Cleaning the showerhead 20 Cleaning the f...

Страница 3: ...king the electrical connections 3 ELECTRICAL 3 1 The installation must comply with BS 7671 Requirements for electrical installations IEE wiring regulations building regulations or any particular regul...

Страница 4: ...mines the water temperature The slower the flow the hotter the water becomes the faster the flow the cooler the water b During winter the mains water supply will be cooler than in the summer so the fl...

Страница 5: ...tch flag assembly 8 Stabilising valve 9 Terminal block 10 Earth connection 11 Solenoid valve 12 Water inlet 13 Thermal cut out outlet 14 Pressure relief device PRD 15 Shower outlet Inside cover fig 2...

Страница 6: ...e connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circuit or cooker circuit 3 1 The electrical supply must be adequate for the l...

Страница 7: ...hose rooms must be protected by a 30mA RCD 9 To obtain full advantage of the power provided by the shower use the shortest cable route possible from the consumer unit to the shower 9 1 The current car...

Страница 8: ...it may not be possible to achieve optimum performance from the unit throughout the year During periods of high ambient temperatures it may be necessary to select a low power setting to achieve your d...

Страница 9: ...ck valve or similar must be fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed into the shower unit which complies with European...

Страница 10: ...ide entry is required the cover will have to be cut out Carefully remove the appropriate area by using a knife or junior hacksaw fig 10 If installing a feed pipe from the back or bottom the centre of...

Страница 11: ...plasterboard or a soft building block you must use suitable wall plugs and an appropriate drill Screw the bottom fixing screw into position leaving the base of the screw head protruding 6mm out from...

Страница 12: ...be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris to waste Procedure Turn off the water supply either at the mains stopvalve or th...

Страница 13: ...erheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through con...

Страница 14: ...the cold position fig 17 Offer the cover to the backplate unit Attached to the stop start switch inside the cover is a two wire lead The socket on the end of this lead must be connected to the plug t...

Страница 15: ...PRD to operate Turn on the mains water supply to the shower at the isolating stop valve and then turn on the electric supply to the shower at the isolating switch The power indicator will light Press...

Страница 16: ...required for the unit cannot be met due to low water pressure it will be necessary to operate the unit on this setting during the warmer months because of flow rate limitations entering the unit Full...

Страница 17: ...the flow of water through the shower and be indicated by the blue arrows To increase the shower temperature Turn the temperature control clockwise this will decrease the flow of water through the sho...

Страница 18: ...fficient and operating difficulties may be encountered A green indication shows that water pressure is sufficient for satisfactory operation of the shower Overheat cut out During normal operation if a...

Страница 19: ...racket end fig 26 Locate the second bracket on top of the rail Check the rail is vertical then mark the centre hole and of the other two holes Remove the bracket and rail Drill and plug the wall Fit t...

Страница 20: ...below the dish The collar is slightly tapered and should be fitted thinner section uppermost Make sure it locates firmly in the soap dish so it holds the dish at the required height on the rail Fitti...

Страница 21: ...c shower 19 ADJUSTING THE SHOWERHEAD Five showerhead patterns are available fig 36 Adjust the spray pattern by turning the bezel on the showerhead in either direction until the desired pattern is obta...

Страница 22: ...reaches a STOP Hold the cartridge firmly and continue to twist anti clockwise Having loosened the sprayplate it can be unscrewed and removed completely Clean the sprayplate with a suitable brush or pr...

Страница 23: ...nd removal of the compression fitting Also depending on the incoming pipework arrangements if there is not enough slack in the pipework it could mean the removal of the unit from the wall When cleanin...

Страница 24: ...00160 10 5kW 83000160 6 Stabiliser valve assembly 8 5kW 9 5kW 82600550 10 5kW 82600760 7 Solenoid valve assembly 83300450 Eaton 8 Outlet pipe assembly c w wires PRD 8 5kW 9 5kW 82200510 10 5kW 8500018...

Страница 25: ...3 SPARE PARTS Ref Description Part No 13 5 mode kwik kleen showerhead 22011270 14 Brackets pair 83306160 15 Riser rail 7042409 16 Showerhead holder 83306190 17 Soap dish 22008960 18 Flexible hose 2810...

Страница 26: ...blocked sprayplate in showerhead 2 2 1 Check if stop valves are fully open Check if blockage in inlet filter 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy power 3 1 1 See Water...

Страница 27: ...ter pressure resumes to normal 6 1 1 Clean or replace blocked sprayplate in showerhead and then fit new PRD 6 2 1 Check for free passage through hose Replace the hose if necessary and fit new PRD 6 3...

Страница 28: ...order 2 By telephone quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk Triton Standard Guarantee Triton Plc guarantee this product against all mechanical and e...

Страница 29: ...Pdf Supplied By http www plumbworld co uk...

Отзывы: