USER MAINTENANCE
It is recommended that the shower unit, riser
rail, hose etc. be cleaned using a soft cloth and
that the use of abrasive or solvent cleaning
fluids be avoided.
It is advised before cleaning, that the isolation
switch be turned off, thus avoiding accidental
switching on of the shower. IT IS MOST
IMPORTANT TO KEEP THE SPRAYHEAD CLEAN
IN ORDER TO MAINTAIN THE PERFORMANCE
OF THE SHOWER. The hardness of the water
will determine the frequency of cleaning.
Sprayplate and cartridge removal
There is no need to remove the sprayhead
from the hose.
Using the removal tool supplied (fig.37), locate
the three raised ’bosses’ into the three
recesses in the sprayplate. Hold in firmly and
twist anti-clockwise (fig.38). This movement
may turn the cartridge assembly as well until it
reaches a ‘stop’. Hold the cartridge firmly and
continue to twist anti-clockwise. Having
loosened the sprayplate sufficiently, it can be
unscrewed and removed completely (fig.39).
To remove the cartridge, hold firmly and turn
anti-clockwise until it unscrews from the
sprayhead (fig.40).
Clean the sprayplate and cartridge with a
suitable brush or preferably leave them to soak
overnight in a mild proprietary descalent.
Ensure all traces of scale are removed and
thoroughly rinse in clean water afterwards.
Before replacing the sprayplate and cartridge,
switch the power back on at the isolating
switch, direct the hose and sprayhead to
waste, select the COLD setting, turn the
temperature control fully anti-clockwise and
press the start/stop button. This operation will
flush out any loose scale deposits in the unit.
Stop after approximately 30 seconds.
Refit the sprayplate and cartridge by screwing
both in clockwise. Use the tool to screw in the
sprayplate tight.
Removal tool
Sprayplate
Cartridge
WARNING
Do no t
use ‘ pow er f ul ’ abrasive or
solvent cleaning fluids when cleaning
the shower as they may damage the
plastic fittings
T8 0 s i
16
Fig.37
Sprayplate
Fig.38
Fig.39
Cart ridge
Fig.40
Содержание Topaz T80si