FAULT FINDING
17
1
Shower inoperable,
no water flow.
2
Water too hot.
3
Water temperature
cycling hot/cool at
intervals.
4
Water too cool or
cold.
5
Shower varies from
normal temperature
to cold during use.
6
Pressure relief
device has operated
(water ejected from
PRD tube).
Note:-
Identify cause
of operation before
fitting new PRD unit.
When fitting a new
PRD, follow the
commissioning
procedure.
1.1
Interrupted power
supply.
1.2
Unit malfunction.
2.1
Not enough water
flowing through the
shower.
2.2
Blockage in supply.
2.3
Increase in ambient
water temperature.
3.1
Heater cycling on
outlet thermal cut- out.
4.1
Too much flow.
4.2
Water pressure
below minimum required
(see rating label).
4.3
Reduction in ambient
water temperature.
4.4
Electrical
malfunction.
5.1
Water pressure has
dropped below minimum
required.
6.1
Blocked sprayhead.
6.2
Twisted/blocked
flexible shower hose.
6.3
Sprayhead not
removed whilst
commissioning.
1.1.1
Blown fuse or circuit breaker. Check supply.
Renew or reset fuse or circuit breaker. If it fails
again, consult a qualified electrician.
1.1.2
Power cut. Check other appliances and if
necessary, contact local Electricity Supply Co.
1.2.1
Have unit checked. Ring Customer Service.
2.1.1
Increase flow rate via temperature control.
2.1.2
Blocked sprayhead - clean or replace blocked
sprayplate in sprayhead.
2.2.1
Check if stop valves are fully open. Check if
blockage in inlet filter.
2.3.1
Re-adjust flow rate to give increased flow.
2.3.2
Select ‘economy’ power.
3.1.1
See
'Water too hot'
causes 2.1, 2.2 and 2.3
and their appropriate action/cures. If it continues,
contact Triton Customer Service.
4.1.1
Reduce flow rate via temperature control.
4.2.1
Is water supply mains or tank fed ?
4.2.2
If tank fed, re-plumb to mains water supply
or see 4.2.4.
4.2.3
If mains fed, ensure that mains stopvalve is
fully open and that there are no other restrictions
in the supply while shower is in use, or see 4.2.4.
4.2.4
Fit pump to give minimum pressure (see
rating label). Contact Customer Service for advice.
4.3.1
Re-adjust flow rate to give reduced flow.
4.3.2
Select ‘high’ power.
4.4.1
Have unit checked by suitably qualified
electrician or contact Triton Customer Service.
5.1.1
Wait until the water pressure resumes to
normal.
6.1.1
Clean or replace blocked sprayplate in
sprayhead and then fit new PRD.
6.2.1
Check for free passage through hose.
Replace the hose if necessary and fit new PRD.
6.3.1
Fit new PRD. Commission unit with
sprayhead removed.
Problem/Symptom
Cause
Action/Cure
It is advised all electrical maintenance/repairs to the shower be carried out by a suitably qualified person.