Страница 1: ...Installation and operating instructions Shannon electric shower T00310 2180424F July 2009 Installers please note these instructions are to be left with the user ...

Страница 2: ...11 Replacing the cover 12 Commissioning 13 Operating the shower 14 Operating functions 16 Instructions for installers and service engineers only 17 Spare parts 18 19 Fault finding 20 21 Guarantee service policy etc rear cover CONTENTS Page To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Telephone ...

Страница 3: ... and could also cause the Pressure Relief Device in the unit to operate This product is not suitable for mounting into steam rooms or steam cubicles PLUMBING The plumbing installation must comply with Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS 6700 The supply pipe must be flushed ...

Страница 4: ...ate and possibly damage the sealing rubber The electric heating elements operate at a constant rate at your chosen power setting It is the rate of the water passing through the heater unit which determines the shower temperature at any given setting The slower the flow the hotter the water becomes and the faster the flow the cooler the water During winter mains water supply will be cooler than in ...

Страница 5: ... selector assembly 6 Can and element assembly 7 Pressure switch flag assembly 8 Stabilising valve 9 Terminal block 10 Earth connection 11 Solenoid valve 12 Water inlet 13 Thermal cut out outlet 14 Pressure relief device PRD 15 Shower outlet 255 mm 300 mm 58 mm 208 mm t00311 Fig 1 Note Not all wiring is shown for reasons of clarity 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 3 2 3 ...

Страница 6: ...tch without the use of a plug or socket outlet 6 2 The switch must be accessible and clearly identifiable but out of reach of a person using a fixed bath or shower except for the cord of a cord operated switch and should be placed so that it is not possible to touch the switch body while standing in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Whe...

Страница 7: ...p and cable size there is a maximum permissible circuit length 9 The shower circuit should be separated from other circuits by at least twice the diameter of the cable or conduit 9 1 The current rating will be reduced if the cabling is bunched with others surrounded by thermal loft or wall insulation or placed in areas where the ambient temperature is above 30 C Under these conditions derating fac...

Страница 8: ...Pa 10 bar If in any doubt the pressure should be checked Note If the stated flow rate is not available it may not be possible to achieve optimum performance from the unit throughout the year During periods of high ambient temperatures it may be necessary to select a low power setting to achieve your preferred shower temperature The water supply can be taken from a cold water storage cistern provide...

Страница 9: ...ating switch and stopvalve Contact Customer Service for advice on replacing the PRD Siting of the shower S 001 A SITING OF THE SHOWER FOR EASE OF SERVICING THE UNIT MUST ALWAYS BE MOUNTED ON THE SURFACE OF TILED WALLS NEVER TILE UP TO THE UNIT Refer to Fig for correct siting of shower Position the unit where it will not be in direct contact with water from the showerhead Position the shower unit v...

Страница 10: ...the bottom of the cover fig 8 If a side entry is required the cover will have to be cut out Carefully remove the appropriate area by using a knife or junior hacksaw fig 9 If installing a feed pipe from the back or bottom the centre of the inlet valve to the wall surface is 20 mm fig 10 Note If entry is from the back the nut of the compression fitting will be partially behind the surface of the wal...

Страница 11: ...ok the backplate over the bottom screw and fit the top fixing screw into position DO NOT fully tighten the screws at this stage as the fixing holes are elongated to allow for out of square adjustment after the plumbing connections have been completed T00318 Fig 11 T00316 Fig 9 t00317 20 mm Fig 10 ...

Страница 12: ...y long enough to clear the debris to waste Procedure Turn off the water supply either at the mains stopvalve or the isolating stopvalve Connect the mains water supply to the inlet of the shower via 15 mm copper stainless steel or plastic pipe using a 15 mm x 15 mm compression fitting Note The inlet fitting is designed to enter a compression fitting only Do not use push fit connectors as full engag...

Страница 13: ... supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by embedding in the wall in accordance with IEE regulations The use of connections within the unit or other points in the shower circuit to supply power to other equipment i e extractor fans pump...

Страница 14: ...e the cover and position the temperature control knob so that it points towards the No 1 position fig 15 Position the power selector to the stop position fig 16 Replace the cover squarely to the backplate and guide into position so that the knobs locate correctly into the splined spindles Should any difficulty arise recheck the points above Secure the cover in position with the three retaining scr...

Страница 15: ...0 may cause the PRD to operate Turn on the mains water supply to the shower at the isolating stop valve and then turn on the electric supply to the shower at the isolating switch The power indicator will light Switch the power selector to the COLD position fig 19 and wait until water starts to flow from the flexible hose Slowly rotate the temperature control fully anti clockwise to 1 the maximum f...

Страница 16: ...ting will only alter the force of the water from the showerhead It will not alter the water temperature Single red symbol is the ECONOMY setting for using less power during warmer months Temperature adjustment at this setting is via the temperature control Note If the stated flow rate required for the unit cannot be met due to low water pressure it will be necessary to operate the unit on this set...

Страница 17: ...he shower and is indicated by the lower numbers To increase the shower temperature Turn the temperature control clockwise this will decrease the flow of water through the shower and is indicated by the higher numbers Note It is advisable to be certain that the showering temperature is satisfactory by testing with your hand before stepping under the showerhead There will always be a time delay of t...

Страница 18: ...if an overheat temperature is sensed power to the elements will be reduced Water will continue to flow When the temperature has cooled sufficiently power to the elements will be automatically restored to the previous setting at the time of interruption Safety cut out The unit is fitted with a thermal cut out safety device In the event of abnormal operation which could cause unsafe temperatures wit...

Страница 19: ...side the solenoid inlet fig 25 To gain access to the filter remove the cover and disconnect and remove the compression fitting Also depending on the incoming pipework arrangements if there is not enough slack in the pipework it could mean the removal of the unit from the wall When cleaning the filter do not use a sharp object as it will cause damage It is preferable to use an old toothbrush or sim...

Страница 20: ...0 5 Thermal cut out main 22009860 6 Stabiliser valve assembly 82600550 7 Outlet pipe wiring assembly 85000250 8 Pressure Relief Device 82800450 9 Cover assembly c w knobs 84800080 Power neon 82300980 Terminal block live wire assembly 82301000 10 Insert trim cover 7052245 11 Insert trim backplate 7052244 Spare parts SPARE PARTS Ref Description Part No t00331 1 2 3 4 5 6 7 8 9 10 11 ...

Страница 21: ...ower 19 SPARE PARTS Ref Description Part No 12 Hose retaining ring 7052252 13 Flexible hoses are available in the following sizes 1 00 m in white chrome and gold 1 25 m in white chrome and gold 1 75 m in chrome only 12 13 ...

Страница 22: ... the supply while shower is in use or see 4 2 4 Fit pump to give minimum pressure see rating label Contact Customer Service for advice Readjust flow rate to give reduced flow Select high power Blown fuse or circuit breaker Check supply Renew or reset fuse or circuit breaker If it fails again consult a qualified electrician Have unit checked by suitably qualified electrician or contact Triton Custo...

Страница 23: ...1 6 1 1 6 2 1 6 3 1 ambient water temperature Interrupted power supply Electrical malfunction or safety cut out operated Water pressure has dropped below minimum required Blocked showerhead Twisted blocked flexible shower hose Showerhead not removed while commissioning 4 4 4 5 5 1 6 1 6 2 6 3 Shower varies from normal temperature to cold during use Pressure relief device has operated water ejected...

Страница 24: ...Shannon electric shower 22 ...

Страница 25: ...Shannon electric shower 23 ...

Страница 26: ...Shannon electric shower 24 ...

Страница 27: ...Shannon electric shower 25 ...

Страница 28: ... Showers Triton Road Nuneaton Warwickshire CV11 4NR Triton is a division of Norcros Group Holdings Limited earthridge Customer Service republic of ireland 01 628 6711 01 628 6845 Service Policy In the event of a complaint occurring thefollowing procedure should be followed 1 Telephone Customer Service on 01 628 6711 or 01 628 6845 having available the model number and power rating of the product t...