background image

Manual mixer shower

8

IMPORTANT: 

Make sure that all the supply 

pipework has been flushed through before 
fitting the mixer

 (fig.11).

Fitting to the wall

Fit the trim onto the inlet water pipes followed 
by the nut and olive 

(fig.12)

.

Connect the hot water supply to the inlet 
marked 

HOT

, ‘

H

’ or red/orange label and 

connect the cold water supply to the inlet 
marked 

COLD

, ‘

C

’ or blue label 

(fig.12)

.

Tighten all compression fittings.
Tighten all the grub screws to secure the mixer 
to mounting plate.

FITTING THE CONTROL LEVER

Push the control lever onto the valve. Using 
an Allen key, secure the lever to the valve by 
tightening the screw on the underside of the 
lever and fit the trim 

(fig.13)

.

COMMISSIONING

Check that both hot and cold water supplies 
are fully open and at (or near to) their design 
temperature and pressures are within the 
requirements as stated. 
Check the mixer can supply the maximum hot 
and maximum cold water demands.

HOT

COLD

Trim

Nut

Olive

Fig.12

Grub screw

in recess

Fig.13

Fig.11

Содержание Kaho

Страница 1: ...se note these instructions are to be left with the user CAUTION THIS PRODUCT IS NOT THERMOSTATICALLY CONTROLLED The showerhead and hose supplied with this product are an integral part of the safety of...

Страница 2: ...N COMPONENTS 1 INTRODUCTION 2 SITE REQUIREMENTS 2 SAFETY WARNINGS 2 PLUMBING REQUIREMENTS 3 WATER SYSTEM REQUIREMENTS 3 TYPICAL SUITABLE INSTALLATIONS 4 5 SITING OF THE SHOWER 6 FITTING THE MIXER 7 BO...

Страница 3: ...ixing plinth 4 Outlet adaptor 5 Blanking plug 6 Elbows and fittings X2 7 Olive nut trim X2 All dimensions listed in this fitting book regarding the product and installation are approximate All kits an...

Страница 4: ...e must not be exceeded Pressure reducing valve On sites where the running pressure is above 5 bar the use of a suitably sized pressure reducing valve fitted in the cold mains supply pipework can provi...

Страница 5: ...ns that easily accessible in line filters are used to aid maintenance Hard water areas a If it is intended to operate the shower in areas of hard water above 200 ppm temporary hardness a scale inhibit...

Страница 6: ...with an unvented stored hot water cylinder For systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when...

Страница 7: ...mal store manufacturer Gravity fed systems fig 5 The shower control MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressures There MUST be a minimum of one metr...

Страница 8: ...ies showerhead riser rail can be positioned above or to either side of the shower refer to fig 6 Supply pipework Complete the pipework to the shower area having decided on the position of the shower a...

Страница 9: ...mounting plate onto the wall fig 8 The inlet elbows allow for either rising falling or rear entry hot and cold water supplies The elbow adapters have two O ring seals fig 9 to the body and do not requ...

Страница 10: ...all compression fittings Tighten all the grub screws to secure the mixer to mounting plate FITTING THE CONTROL LEVER Push the control lever onto the valve Using an Allen key secure the lever to the va...

Страница 11: ...t the water temperature turn the control lever clockwise for a hotter shower and anti clockwise for a cooler shower fig 15 To stop the shower To start the shower Anti clockwise for cooler Clockwise fo...

Страница 12: ...wer head connected Important Product flow rates are for guidance only CLEANING DO NOT use abrasive or solvent cleaning fluids The shower unit riser rail hose etc should be cleaned using a soft cloth a...

Страница 13: ...Manual mixer shower 11 All dimensions listed in this fitting book regarding the product and installation are approximate DIMENSIONS 100mm 130mm 150mm 1 2 BSP...

Страница 14: ...enuine Triton spare part for your product please visit www tritonshowers co uk spares for product codes and prices Alternatively please call our Customer Services team on 024 7637 2222 to order direct...

Страница 15: ...4 1 Reduce the simultaneous demand from the mains supply 2 1 1 Turn the control lever clockwise 2 2 1 Turn the control lever clockwise 2 3 1 Make sure heating appliance is set to maximum or has suffi...

Страница 16: ...or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please...

Отзывы: