SITE REQUIREMENTS

The installation must be in accordance with Water
Regulation Byelaws and BS6700.

Minimum running water pressure: 0.2 bar.

Maximum running water pressure: 5 bar.

Maximum static water pressure: 10 bar.

For optimum performance within the specified
running pressure range a minimum flow of 8 litres
per minute should be available to both inlets.

Whilst the mixer valve is operational (open outlet),
inlet pressures must not be capable of exceeding 7
bar. For effective operation of the internal seals,
the maximum static pressure must not be
exceeded.

NOTE: On sites where the running pressure is
above 5 bar, the use of a suitably sized pressure
reducing valve fitted in the cold mains supply
pipework can provide nominally equal pressures at
the mixer valve.

For optimum performance of this shower both hot
and cold water supplies to the shower valve
should be fed at nominally equal pressures.

The pipework should be installed such that the
flow is not significantly affected by other taps and
appliances being operated elsewhere on the
premises.

NOTE: Where thermal store/combi boilers or
multi-point heaters are used, if excessive draw offs
take place the boiler may not be able to maintain
an adequate output temperature. This could result
in the shower temperature becoming noticeably
cooler.

Water temperature requirements

Maximum hot water temperature

80°C

Recommended maximum

65°C

Minimum hot water temperature

52°C

Maximum cold water temperature

20°C

BS6700 recommends that the temperature of
stored water should never exceed 65°C.
A stored water temperature of 60°C is considered
sufficient to meet all normal requirements and will
minimise the affects of scale in hard water areas.

H

O

T

C

O

L

D

O

N

O

F

F

T

R

IT

ON SHOW

E

R

S

CH flow

Cold mains supply

Hot
water

CH return

Service

valves

Mixer

valve

Stop tap

Pressure

reducing

valve

Combination

boiler

Fig.3  

(

diagrammatic

view  – not to scale)

Содержание DC7000 Antique

Страница 1: ...O L D O N O F F T R ITON SHOW E R S Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180290B May 2000 DC7000 dual control Antique mixer...

Страница 2: ...DC7000 ANTIQUE UKAS QUALITY MANAGEMENT 003...

Страница 3: ...wer 6 Installation general 7 8 Installation solid wall 9 hollow wall 10 cubicle or panel 11 Connecting the supply pipes 12 Fitting Showerhead 13 Using the tiling shroud 14 Fitting the face plate and k...

Страница 4: ...en flowrate adjustments are made The valve unit can be fitted in any orientation For a wall mounted sprayhead installation the plumbing will be simplified if the outlet is fitted upwards The valve is...

Страница 5: ...knob 4 On off control knob 5 Tiling shroud 6 Mounting bracket 7 Flat bracket 2 off 8 Sprayhead and arm 9 Tool and screw pack 10 Ceramic on off cap 11 Ceramic temperature cap 12 Trim rings 13 Flow lim...

Страница 6: ...ply pipework can provide nominally equal pressures at the mixer valve For optimum performance of this shower both hot and cold water supplies to the shower valve should be fed at nominally equal press...

Страница 7: ...us water heater the appliance must be capable of raising the temperature of the incoming water by 45 C 81 F and delivering a flow rate of not less than 8 litres per minute A flow limiter is supplied f...

Страница 8: ...time when it is being installed The hot and cold water pipes should not be permanently attached to the wall closer than 2m from the valve prior to installation to allow for final adjustment of the va...

Страница 9: ...tted in any orientation fig 7 but for a wall mounted sprayhead installation the plumbing will be simplified if the outlet is fitted upwards Access to the integral strainers will also be improved with...

Страница 10: ...65 mm fig 9 measured from the face of the wall upon which the mounting bracket is screwed excluding the tile thickness The allowance for varying thickness of tiles up to 10mm is accommodated by a limi...

Страница 11: ...when the installation is complete There is limited tolerance between the control knobs and trim rings to allow for varying thickness of tiles up to 10mm As a guide for the size of hole place the tilin...

Страница 12: ...ying thickness of tiles up to 10mm Mark the route of the incoming and outgoing pipework As a guide for the size of hole place the tile shroud on the wall and trace around it fig 11 Take out the plaste...

Страница 13: ...of the panel or cubicle Use the supplied template as a guide fig 16 After cutting the two holes fit the valve to the mounting bracket and secure using the four screws provided Offer the valve and mou...

Страница 14: ...other sealing means is required Tighten the compression fittings with the cranked spanner supplied for when access is restricted Ensure the on off assembly is turned to the off position by temporarily...

Страница 15: ...oles fig 21 Drill and plug the holes using the plugs supplied NOTE If fitting to a hollow wall structure use suitable cavity wall fixtures Apply PTFE tape to the 1 2 BSP thread on the shower head arm...

Страница 16: ...nsuring the indicator notch is in the 12 o clock position It must be in this position regardless in which orientation the unit is mounted Secure by screwing on the two brass face plate retaining rings...

Страница 17: ...e that should the knobs and faceplate require cleaning then care must be taken not to scratch them in the process Wash away any surface dust before cleaning with soapy water DO NOT USE ABRASIVE CLEANE...

Страница 18: ...an uncontrolled manner then the hot and cold supplies are probably reversed This must be corrected before proceeding further The mixer valve is factory set to provide a maximum outlet temperature of...

Страница 19: ...omer Service In domestic installations where D08 specification is not required the maximum temperature setting should not exceed 45 C OPERATING THE SHOWER To start the shower rotate the on off control...

Страница 20: ...ssioned setting then ensure the strainers are clean and that the isolating valves are fully open Test the non return valves as described below If these tests do not highlight the reason for the temper...

Страница 21: ...f the hot supply and ensure the cold supply is open Be prepared for leakage of trapped water in the pipe and remove the strainer basket on the hot side Evidence of continuing leakage from the strainer...

Страница 22: ...Spray arm chrome 22009380 gold 22009390 7 Sprayhead chrome 22009340 gold 22009330 8 Mounting bracket 7012435 9 Flat bracket 7012436 Bracket assembly 83306290 comprising 8 9 10 Utilities pack 7102523 c...

Страница 23: ...sioning details Hot water temp C Pressure Bar Equip used Cold water temp C Pressure Bar Equip used Max temp setting C C W fail C max Replacement dates O ring seals recommended every 3 years Thermostat...

Страница 24: ...specification 1 4 1 Clean refer to maintenance section 1 5 1 Replace refer to maintenance section 2 1 1 Turn temperature control anti clockwise 2 2 1 Turn temperature control anti clockwise 2 3 1 Ens...

Страница 25: ...23 DC7000 ANTIQUE...

Страница 26: ...DC7000 ANTIQUE 24...

Страница 27: ......

Страница 28: ...rma invoice by cheque or money order 2 By telephone quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk Triton Plc Shepperton Park Caldwell Road Nuneaton Warwicks...

Отзывы: