valve by performing a thermal shut off test. Shut
off the cold supply. The flow from the shower
should stop immediately or reduce to a trickle in
which case the water temperature should be less
than 43°C.
In either case there is no risk of scalding.
If however the temperature is above 43°C then it
is likely there is contamination in the valve
preventing it from shutting off the hot supply. In
this case refer to the maintenance section or
contact Customer Service.
In domestic installations where D08 specification is
not required, the maximum temperature setting
should not exceed 45°C.
OPERATING THE SHOWER
To start the shower, rotate the on/off control fully
anti-clockwise (fig.29) for maximum flow.
To stop the water flow, rotate the on/off control
fully clockwise (fig.30) until resistance is felt.
To adjust the water temperature, rotate the
temperature control – clockwise in the direction of
the cold arrow (fig.31) for a cooler shower or anti-
clockwise in the direction of the hot arrow (fig.32)
for a hotter shower.