b) Valve installation in a solid wall
Remove the tiling shroud if fitted to the valve unit.
The shroud is retained by a 2.5mm hex socket
screw, replace the screw in the valve immediately
to avoid it being lost.
Decide on the shower position and determine
whether the hot and cold water supplies will enter
the shower from the top (falling) or bottom
(rising) or rear.
The building depth should be at least 70mm deep
from the surface of the wall. It is recommended to
use the supplied mounting bracket (fig.10) at all
times when installing the shower valve. It provides
the correct visible amount of shower control
through the face plate when the installation is
complete. There is limited tolerance between the
control knobs and trim rings to allow for varying
thickness of tiles up to 10mm.
As a guide for the size of hole, place the tiling
shroud on the wall and trace around it (fig.11).
Remove the plaster and brickwork to the required
depth and chase out any additional areas of the
wall to facilitate pipework to and from the valve.
Offer the mounting bracket up to the wall and
mark the four outer plain holes (fig.12). Remove
the bracket then drill and plug the wall. Screw the
bracket to the wall. Route the pipework to valve
position.
Flush out the pipework in accordance with
Water Regulation Byelaws .
Offer the valve up to the mounting bracket, and
secure using the four screws provided.
Proceed to ‘connecting supply pipes’ section.
135 mm
maximum
235 mm
maximum
Fig.10
Fig.11
Fig.12