background image

Triton Showers 

Triton Road 

Nuneaton 

Warwickshire  CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Customer Service: 

0844 980 0750

Trade Installer Hotline: 

0844 980 0730 

Fax: 

 

0844 980 0744

www.tritonshowers.co.uk 

E-mail: [email protected]

TRITON reserve the right to change product specification without prior notice. E&OE. © TRITON SHOWERS 2012

Extended Warranty AVAILABLE NOW. Call 0844 980 0740 for more details.

UK SERVICE POLICY

In the event of a product fault or complaint occurring, the following 

procedure should be followed:

1. 

Telephone Customer Service on 

0844 980 0750

 having available, 

your details including post code, the model number and power 

rating of the product, together with the date of purchase and, where 

applicable, details of the particular fault.

2. 

If required, the Customer Service Advisor will arrange  

for a qualified engineer to call.

3.

  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 

applicable to the product. 

(Every product pack contains an installation 

guide, however, they can also be bought via our Customer Service Spares 

Department)

.

4.

  Our engineer will require local parking and if a permit is required this 

must be available to the engineer on arrival at the call. 

5.

  It is essential that you or an appointed representative 

(who must 

be over 18 years of age)

 is present for the duration of the service 

engineer's visit. If the product is in guarantee you must produce 

proof of purchase.

6.

  Where a call under the terms of guarantee has been booked and 

the failure is not product related 

(i.e. scaling and furring, incorrect 

water pressure, pressure relief device operation or electrical/plumbing 

installation fault)

 a charge will be made. A charge will also be issued 

if nobody is at home when the service engineer calls or adequate 

parking/permit is not available.

7.

  If the product is no longer covered by the guarantee an up front 

fixed fee will be charged before the site visit.

8.

  Should proof of purchase not be available on an “in-guarantee” call, 

or should the service engineer find that the product is no longer 

under guarantee, the engineer will charge the same fixed price and 

the customer will be expected to pay the engineer before he leaves. 

If payment is not made on the day an administration charge will be 

added to the fixed charge.

9.

  If a debt is outstanding from a previous visit, or from any other Triton 

purchase. Triton reserves the right to withhold service until the debt 

has been settled.

10.

  Triton takes the health, safety and wellbeing of its employees very 

seriously and expects customers to treat all staff members with respect. 

Should any employee feel threatened or receive abuse, either verbally 

or physically, Triton reserves the right to withhold service and will 

support the employee with a legal prosecution.

Replacement Parts Policy

It is the policy of Triton Showers to maintain parts availability for the 

duration of production and a period of 5 years thereafter in accordance 

with industry standards. In the event of a spare part not being available a 

substitute part will be supplied.
Spare parts can be ordered via our online spare parts store, or by 

telephoning Triton Spares Department. Payment should be made by 

credit/debit card 

(excluding American Express or Diners Card)

. Payment 

can also be made by pre-payment of a pro-forma invoice, by cheque or 

postal order.
Telephone orders are based on information given during of the call. 

Before contacting Triton, please verify your requirements using the 

information contained in the user guide. Triton cannot accept liability for 

incorrect part identification.

TRITOn STandaRd GUaRanTEE

Triton guarantee this product against all 

mechanical and electrical defects arising from 

faulty workmanship or materials for a period of 

one year for domestic use only, from the date of 

purchase, provided that it has been installed by 

a competent person in full accordance with the 

fitting instructions. 
Any part found to be defective during this 

guarantee period we undertake to repair or replace 

at our option without charge so long as it has been 

properly maintained and operated in accordance 

with the operating instructions, and has not been 

subject to misuse or damage. 
This product must not be taken apart, modified or 

repaired except by a person authorised by Triton. 

This guarantee applies only to products installed 

within the United Kingdom and does not apply to 

products used commercially. This guarantee does 

not affect your statutory rights. 

What is not covered: 
1.

  Breakdown due to: 

a)

 use other than domestic 

use by you or your resident family; 

b)

 wilful act 

or neglect; 

c)

 any malfunction resulting from the 

incorrect use or quality of electricity, gas or water 

or incorrect setting of controls; 

d)

 failure to install 

in accordance with this installation guide. 

2.

  Repair costs for damage caused by foreign 

objects or substances.

3.

  Total loss of the product due to non-availability 

of parts.

4.

  Compensation for loss of use of the product or 

consequential loss of any kind.

5.

  Call out charges where no fault has been found 

with the appliance.

6. 

Call out charges where the water supply cannot 

be isolated, this includes consequential losses 

arising from unserviceable supply valves.

7. 

The cost of repair or replacement of pressure 

relief devices, showerheads, hoses, riser rails 

and/or wall brackets, isolating switches, 

electrical cable, fuses and/or circuit breakers or 

any other accessories installed at the same time.

8. 

The cost of routine maintenance, adjustments, 

overhaul modifications or loss or damage arising 

therefrom, including the cost of repairing 

damage, breakdown, malfunction caused by 

corrosion, furring, pipe scaling, limescale, 

system debris or frost.

3-1-2012

Содержание AS2000X

Страница 1: ...Installers please note these instructions are to be left with the user 2180403L June 2012 Installation and operating instructions AS2000X power shower...

Страница 2: ...onnections 11 Commissioning 12 14 Fitting the riser rail 15 16 Operating the shower 17 18 Adjusting the maximum temperature stop 18 Cleaning the filters 19 Spare parts 20 Fault finding 21 22 Water Cab...

Страница 3: ...1 9 1 The anticipated flow rate may not be achieved 1 9 2 Air may be drawn into the hot supply from the vent pipe causing spluttering and temperature fluctuations at the showerhead 1 10 Fullway isola...

Страница 4: ...could cause injury b Under no circumstances must this product be connected to mains cold or hot water supplies Failure to comply will invalidate the guarantee c The shower MUST NOT be used if suspecte...

Страница 5: ...nimum static inlet pressure 0 75 Kpa 0 0075 bar or 75mm required to prime the integral centrifugal pump Maximum supply head 10m SPECIFICATIONS MAIN COMPONENTS 1 Top pipe entry and cable entry 2 Termin...

Страница 6: ...supply Isolating valve Cold water cistern Vent pipe tee Isolating valve Hot supply Hot water cylinder Drain valve Other hot water draw offs Alternative connection Shower unit Ring main 25mm min Isola...

Страница 7: ...work 4 Shower control MUST be fed from a cold water storage cistern and hot water cylinder that provides nominally equal pressures Fig 3 Diagrammatic view not to scale 5 The unit must be mounted onto...

Страница 8: ...r and showerhead on the wall so that all controls can be comfortably reached when using the shower The showerhead and riser rail can be positioned either side of the shower unit Note Water Regulations...

Страница 9: ...O NOT let the unit dangle by the lead PLUMBING CONNECTIONS Plumbing to be carried out before wiring Note The outlet of the shower must not be connected to anything other than the hose and showerhead s...

Страница 10: ...TANT For rear entry only the supplied elbows must be used For ease of installation the backplate area adjacent to the top pipe inlet must be cut out including the top left wall fixing hole When fittin...

Страница 11: ...re fitted to the top pipe inlets These should be left in position if bottom pipe entry is required For top or rear pipe entry the two plugs MUST be removed and refitted into the bottom pipe inlets Fai...

Страница 12: ...up to the completed pipework and manoeuvre so that the end of the pipes enter fully into the inlet fittings Mark positions for wall fixing holes using backplate as template fig 17 Note that four fixi...

Страница 13: ...ion is trapped under the screws Note The supply cable earth conductor must be sleeved The earth continuity conductor of the electrical installation must be effectively connected electrically to all ex...

Страница 14: ...ng link is positioned on the middle two pins fig 21 Switch on the electric supply at the isolating switch Water will begin to flow under gravity pressure Once the unit has been commissioned disconnect...

Страница 15: ...ommissioning link from the PCB fig 23 and store safely for future use Inside the cover attached to the flow control potentiometer is a 4 wire lead Fit the connector on the end of this lead to the 4 pi...

Страница 16: ...on Adjusting the maximum temperature stop Replace the temperature control onto the valve spindle Make sure the pointer aligns with setting 9 on the temperature disc fig 29 Secure with the retaining sc...

Страница 17: ...ing the brackets as templates mark two upper holes and two lower holes Note there are four provisions for screws per bracket select the two most suitable for your requirements Make sure the rail is al...

Страница 18: ...rhead checking the supplied washers are in place at both ends of the flexible hose fig 38 Place the showerhead into the holder and check that it fits correctly fig 39 Note The holder is slightly taper...

Страница 19: ...ched off at the electricity isolating switch As a safety feature the temperature control has a built in stop to prevent you accidentally exceeding your highest desired temperature If adjustment is req...

Страница 20: ...sc Remove the cover trim to reveal the retaining screw fig 44 Undo the retaining screw and carefully pull off the temperature control making sure it is still aligned to setting 9 Now remove the maximu...

Страница 21: ...he O rings are in position Refit the filter cover and secure with the retaining screw Make sure the potentiometer control is rotated fully anti clockwise fig 25 With your fingers rotate the valve spin...

Страница 22: ...0 7 PCB unit 7073738 8 Solenoid assembly 22012190 9 Gear 7052184 10 Filter pair 83305330 Pipe trim 7052146 Pipe removing tool 7052144 Potentiometer harness P09440900 Bracket 7052183 Wire kit 83311410...

Страница 23: ...a competent electrician 3 1 2 Power cut Check other appliances and if necessary contact local Electricity Supply Co 3 2 1 Consult a competent electrician or contact Customer Service 3 3 1 Thermal prot...

Страница 24: ...lugs into unused inlets 4 Water does not flow or is reduced 5 Cross flow of hot and cold water into system 6 Water dripping from showerhead when turned off 7 Pump is noisy or air lock in pump 8 Unit r...

Страница 25: ...Aquasensation AS2000X 23 Entry Points Diagram Key Water Entry Points Cable Entry Points...

Страница 26: ...Aquasensation AS2000X 24...

Страница 27: ...Aquasensation AS2000X 25...

Страница 28: ...e right to withhold service and will support the employee with a legal prosecution Replacement Parts Policy It is the policy of Triton Showers to maintain parts availability for the duration of produc...