FAULT FINDING
Symptom Cause
Action/Cure
4.1.1
Check water elsewhere in house and if
necessary contact the local Water Company.
4.2.1
Switch off shower and contact Customer
Service.
4.3.1
Clean showerhead.
4.4.1
Clean filters.
5.1.1
Isolate water to unit. Remove check valves.
Clean and replace.
6.1.1
Call Customer Service.
6.2.1
Call Customer Service.
7.1.1
Call Customer Service.
7.2.1
Replace pump.
8.1.1
Fit blanking plugs into unused inlets.
4
Water does not
flow or is reduced.
5
Cross flow of
hot and cold water
into system.
6
Water dripping
from showerhead
when turned off.
7
Pump is noisy or
air lock in pump.
8
Unit running
erratically.
4.1
Water supplies cut off.
4.2
Shower blocked or air
in the system.
4.3
Showerhead blocked.
4.4
Blocked filters.
5.1
Dirt/debris in check
valves.
6.1
Debris in solenoid
valve.
6.2
Potentiometer faulty.
7.1
Air lock in pump.
7.2
Worn pump bearings.
8.1
Blanking plugs not
fitted into unused inlets.
In the unlikely event of a fault occurring please contact Triton Customer service.
DO NOT remove the shower from the installation.