background image

I

nstallers

 

please

 

note

 

these

 

InstructIons

 

are

 

to

 

be

 

left

 

wIth

 

the

 

user

2180403L

 - June 2012

Installation and 

operating

instructions

AS2000X 

power shower

Содержание AS2000X

Страница 1: ...Installers please note these instructions are to be left with the user 2180403L June 2012 Installation and operating instructions AS2000X power shower...

Страница 2: ...onnections 11 Commissioning 12 14 Fitting the riser rail 15 16 Operating the shower 17 18 Adjusting the maximum temperature stop 18 Cleaning the filters 19 Spare parts 20 Fault finding 21 22 Water Cab...

Страница 3: ...1 9 1 The anticipated flow rate may not be achieved 1 9 2 Air may be drawn into the hot supply from the vent pipe causing spluttering and temperature fluctuations at the showerhead 1 10 Fullway isola...

Страница 4: ...could cause injury b Under no circumstances must this product be connected to mains cold or hot water supplies Failure to comply will invalidate the guarantee c The shower MUST NOT be used if suspecte...

Страница 5: ...nimum static inlet pressure 0 75 Kpa 0 0075 bar or 75mm required to prime the integral centrifugal pump Maximum supply head 10m SPECIFICATIONS MAIN COMPONENTS 1 Top pipe entry and cable entry 2 Termin...

Страница 6: ...supply Isolating valve Cold water cistern Vent pipe tee Isolating valve Hot supply Hot water cylinder Drain valve Other hot water draw offs Alternative connection Shower unit Ring main 25mm min Isola...

Страница 7: ...work 4 Shower control MUST be fed from a cold water storage cistern and hot water cylinder that provides nominally equal pressures Fig 3 Diagrammatic view not to scale 5 The unit must be mounted onto...

Страница 8: ...r and showerhead on the wall so that all controls can be comfortably reached when using the shower The showerhead and riser rail can be positioned either side of the shower unit Note Water Regulations...

Страница 9: ...O NOT let the unit dangle by the lead PLUMBING CONNECTIONS Plumbing to be carried out before wiring Note The outlet of the shower must not be connected to anything other than the hose and showerhead s...

Страница 10: ...TANT For rear entry only the supplied elbows must be used For ease of installation the backplate area adjacent to the top pipe inlet must be cut out including the top left wall fixing hole When fittin...

Страница 11: ...re fitted to the top pipe inlets These should be left in position if bottom pipe entry is required For top or rear pipe entry the two plugs MUST be removed and refitted into the bottom pipe inlets Fai...

Страница 12: ...up to the completed pipework and manoeuvre so that the end of the pipes enter fully into the inlet fittings Mark positions for wall fixing holes using backplate as template fig 17 Note that four fixi...

Страница 13: ...ion is trapped under the screws Note The supply cable earth conductor must be sleeved The earth continuity conductor of the electrical installation must be effectively connected electrically to all ex...

Страница 14: ...ng link is positioned on the middle two pins fig 21 Switch on the electric supply at the isolating switch Water will begin to flow under gravity pressure Once the unit has been commissioned disconnect...

Страница 15: ...ommissioning link from the PCB fig 23 and store safely for future use Inside the cover attached to the flow control potentiometer is a 4 wire lead Fit the connector on the end of this lead to the 4 pi...

Страница 16: ...on Adjusting the maximum temperature stop Replace the temperature control onto the valve spindle Make sure the pointer aligns with setting 9 on the temperature disc fig 29 Secure with the retaining sc...

Страница 17: ...ing the brackets as templates mark two upper holes and two lower holes Note there are four provisions for screws per bracket select the two most suitable for your requirements Make sure the rail is al...

Страница 18: ...rhead checking the supplied washers are in place at both ends of the flexible hose fig 38 Place the showerhead into the holder and check that it fits correctly fig 39 Note The holder is slightly taper...

Страница 19: ...ched off at the electricity isolating switch As a safety feature the temperature control has a built in stop to prevent you accidentally exceeding your highest desired temperature If adjustment is req...

Страница 20: ...sc Remove the cover trim to reveal the retaining screw fig 44 Undo the retaining screw and carefully pull off the temperature control making sure it is still aligned to setting 9 Now remove the maximu...

Страница 21: ...he O rings are in position Refit the filter cover and secure with the retaining screw Make sure the potentiometer control is rotated fully anti clockwise fig 25 With your fingers rotate the valve spin...

Страница 22: ...0 7 PCB unit 7073738 8 Solenoid assembly 22012190 9 Gear 7052184 10 Filter pair 83305330 Pipe trim 7052146 Pipe removing tool 7052144 Potentiometer harness P09440900 Bracket 7052183 Wire kit 83311410...

Страница 23: ...a competent electrician 3 1 2 Power cut Check other appliances and if necessary contact local Electricity Supply Co 3 2 1 Consult a competent electrician or contact Customer Service 3 3 1 Thermal prot...

Страница 24: ...lugs into unused inlets 4 Water does not flow or is reduced 5 Cross flow of hot and cold water into system 6 Water dripping from showerhead when turned off 7 Pump is noisy or air lock in pump 8 Unit r...

Страница 25: ...Aquasensation AS2000X 23 Entry Points Diagram Key Water Entry Points Cable Entry Points...

Страница 26: ...Aquasensation AS2000X 24...

Страница 27: ...Aquasensation AS2000X 25...

Страница 28: ...e right to withhold service and will support the employee with a legal prosecution Replacement Parts Policy It is the policy of Triton Showers to maintain parts availability for the duration of produc...

Отзывы: