background image

Push button mixer shower

To check the product suitability for commercial and multiple installations, please contact Triton’s 
specification advisory service before installation. Please see back of book for contact information.

CONTENTS 

Page

MAIN COMPONENTS .............................................................................1

DIMENSIONS .........................................................................................2 

INTRODUCTION.....................................................................................3

PLUMBING & WATER SYSTEM REQUIREMENTS ......................................4

TYPICAL DOMESTIC INSTALLATIONS .................................................5 - 6

PREPARING THE SHOWER .......................................................................7

SITING OF THE SHOWER ........................................................................7

INSTALLATION .................................................................................8 - 12

LEAK TESTING ......................................................................................12

OPERATING THE SHOWER ....................................................................13

COMMISSIONING ................................................................................14

ADJUSTING THE MAXIMUM TEMPERATURE SETTING ...........................15

MAINTENANCE ....................................................................................16

FLOW RATES .........................................................................................17

FAULT FINDING .............................................................................18 - 19

GUARANTEE, SERVICE POLICY, ETC. ......................................... rear cover

I

nstallers

 

please

 

note

 

these

 

InstructIons

 

are

 

to

 

be

 

left

 

wIth

 

the

 

user

Содержание 2181629F

Страница 1: ...BOX ALTERNATIVELY REGISTER BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation...

Страница 2: ...N COMPONENTS 1 DIMENSIONS 2 INTRODUCTION 3 PLUMBING WATER SYSTEM REQUIREMENTS 4 TYPICAL DOMESTIC INSTALLATIONS 5 6 PREPARING THE SHOWER 7 SITING OF THE SHOWER 7 INSTALLATION 8 12 LEAK TESTING 12 OPERA...

Страница 3: ...ush button mixer shower 1 MAIN COMPONENTS A Mixer shower B Riser rail C Wall brackets D Riser rail wall bracket E Slider F Hose not shown G Shower head not shown H Fixed shower head not shown C A D B...

Страница 4: ...mixer shower 2 780 1120mm 10 710mm 7 19mm 22mm 130x50mm 50 67mm 40mm 340mm 5 304mm 140mm 59mm 255x190mm DIMENSIONS All dimensions listed in this fitting book regarding the product and installation are...

Страница 5: ...old supply temperature C Equal to or less than 25 This mixer shower is designed for high pressure systems found in the UK For effective operation of the internal seals the maximum static pressure must...

Страница 6: ...he access point to the isolator Flush pipework to clear the system of debris and check for leaks before connecting to the mixer Commercial Applications For commercial applications in line filters are...

Страница 7: ...pply pressures exceed 5 bar running An expansion vessel MAY be fitted and regularly maintained to prevent the shower mixer being damaged by excess pressures This may already be installed within the bo...

Страница 8: ...reducing valve must be set at the same value as the unvented package pressure reducing valve Note An additional expansion vessel may be required if a second pressure reducing valve is installed This d...

Страница 9: ...carefully covered to stop ingress of any debris while routing the supply pipework The mixer shower is suitable for exposed installation onto solid wall a stud partition wall dry lined wall or fixing t...

Страница 10: ...uld pass through the support studs or noggins via a suitably sized hole fig 6 Decide upon the mounting position of the brackets on the wall and mark the centres Check the mounting marks are level and...

Страница 11: ...the pipework is at rest against the depth of chasing the length of pipe protruding from the wall should be between 25mm MAXIMUM and 21mm MINIMUM from the face of the finished wall or tiles fig 11 Make...

Страница 12: ...cover taking care not to damage the glass Offer the mixer shower to the brackets checking that the sealing washers are in place and carefully tighten the nuts Ensure the distance from the centre of th...

Страница 13: ...and drill and plug the wall An appropriate drill bit should be used If the wall is brick plasterboard or a soft building block use appropriate wall plugs and screws should be used Secure the bracket t...

Страница 14: ...Remedy any leaks found FITTING THE SHOWER HEAD Screw the conical end of the hose to the shower head then locate the shower head into the slider Screw the fixed head to the riser fixed head rail Make...

Страница 15: ...RE CONTROL To adjust the water temperature rotate the temperature control to the desired temperature fig 21 To overcome the maximum temperature stop press the override button and turn DIVERTER CONTROL...

Страница 16: ...ntee user safety Rotate the temperature control checking the minimum and maximum showering temperatatures ADJUST THE MAXIMUM TEMPERATURE STOP SETTING on page 14 if required The following is recommende...

Страница 17: ...res The BuildCert TMV scheme recommends a maximum mixed water outlet temperatures of 41 C for showers The mixed water temperatures must never exceed 46 C The British Burns Association recommends 37 C...

Страница 18: ...of routine maintenance of the internal of the mixer shower will depend mainly on the water supply condition Experience of local conditions will dictate the intervals for inspection and in service test...

Страница 19: ...7 8 0 11 5 14 0 16 5 18 0 Overhead showe head flow rate l m 2 6 3 6 4 0 5 0 5 6 8 0 12 0 15 0 17 0 18 5 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comp...

Страница 20: ...water supply blocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1...

Страница 21: ...4 2 1 Inspect the inlet filters Clean if necessary 4 3 1 Turn off the mixer shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sur...

Страница 22: ...Push button mixer shower 20...

Страница 23: ...Push button mixer shower 21...

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...