background image

In the event of a product fault or complaint occurring, 
the following procedure should be followed:
DO NOT REMOVE THE PRODUCT

1.  Telephone Customer Experience on 

024 7637 2222

 having 

available your details including post code, the model number 
and power rating of the product, together with the date of 
purchase and, where applicable, details of the particular fault.

2.  If required, the Customer Experience Advisor will arrange for a 

qualifi ed engineer to call.

3.  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 
applicable to the product. Every product pack contains an 
installation guide, however, they can also be downloaded free at 
www.tritonshowers.co.uk. 

4.  Our engineer will require local parking and if a permit is required, 

this must be available to the engineer on arrival at the call.

5.  If loft access is required for isolation or to complete a repair, 

the loft must have a fi xed access ladder and be boarded, with 
appropriate lighting from the access point to and around the 
repair area.

6.  It is essential that you or an appointed representative (who must 

be over 18 years of age) is present for the duration of the service 
engineer’s visit. If the product is in guarantee you must produce 
proof of purchase.

7.  Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 
incorrect water pressure, pressure relief device operation or 
electrical/plumbing installation fault) a charge will be made. A 
charge will also be issued if nobody is at the property when the 
service engineer calls or adequate parking/permit is not available.

8.  If the product is no longer covered by the guarantee an 
 

up-front fi xed fee will be charged before the site visit.

9.  Your receipt must be retained as proof of purchase. Should proof 

of purchase not be available on an ‘in-guarantee’ call, or should 
the service engineer fi nd that the product is no longer under 
guarantee, the engineer will charge the same fi xed price and 
will request payment prior to departing. If payment is not made 
on the day an administration charge will be added to the fi xed 
charge.

10.  If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 
the debt has been settled.

11.  Triton takes the health, safety and wellbeing of its employees 

very seriously and expects customers to treat all staff members 
with respect. Should any employee feel threatened or receive 
abuse, either verbally or physically, Triton reserves the right to 
withhold service.

Replacement Parts Policy

In line with AMDEA guidelines, Triton retains functional spares 
for as long as there is a market for them and in most cases, well 
beyond.  Due to the vast array of product types, the life cycle of 
products can vary and therefore so can the length of time parts 
can be supplied. Spare parts can be ordered via our online spare
parts store or by telephoning our Triton Customer Experience
team on 

024 7637 2222

. Payment should be made by

credit / debit card (excluding American Express or Diners Card).
Payment can also be made by pre-payment of a pro-forma
invoice, by cheque or postal order.

Telephone orders are based on information given during 
the call.  Before contacting Triton, please verify your 
requirements using the Information contained in the
user guide. Triton cannot accept liability for incorrect part 
identifi cation. 

TRITON UK STANDARD GUARANTEE

This guarantee applies only to products installed within 
the United Kingdom and does not apply to products used 
expressly for commercial gain, unless this use has been
specifi ed by Triton.  This guarantee does not affect your 
statutory rights.
With the exception of accessories, Triton guarantee the
product against all manufacturing defects for a period of 

5 years

 for use in a domestic environment from the date of 

purchase, provided that it has been installed by a competent 
person in full accordance with the fi tting instructions. 
All accessories such as shower heads, hoses and riser rails carry 

1 year

 parts only guarantee against manufacturing defects.

Any part found to be defective during this guarantee period 
we undertake to repair or replace at our option without 
charge, so long as it has been properly maintained and
operated in accordance with the instructions and has not 
been subject to misuse or damage or the effects of limescale 
build up. This product must not be taken apart, modifi ed or 
repaired except by a person authorised by Triton. 

What is not covered:

1.  Breakdown due to:  

 

a) 

use other than domestic use by the property 

occupants; 

b)

 wilful act or neglect; 

c) 

any malfunction resulting from the incorrect use or 

quality of electricity, gas or water or incorrect setting of 

controls; 

d) 

failure to install in accordance with this installation 

guide.

2.  Claims for missing parts once the product has been 

installed.

3.  Repair costs for damage caused by foreign objects or 

substances.

4.  Total loss of the product due to non-availability of parts.
5.  Compensation for loss of use of the product or 

consequential loss of any kind.

6.  Call out charges due to an abortive visit or where no fault 

has been found with the appliance.

7.  The cost of repair or replacement of isolating switches, 

electrical cable, fuses and/or circuit breakers or any other 

accessories installed at the same time. Replacement of the 

Pressure Relief Device that only activates when the shower 

outlet is blocked is also excluded. 

8.  The cost of routine maintenance, adjustments, overhaul 

modifi cations or loss or damage arising therefrom, 

including the cost of repairing damage, breakdown, 

malfunction caused by corrosion, furring, frost or exposure 

to freezing conditions.

9.  Call out charges where the water supply cannot be 

isolated, this includes consequential losses arising from

 

unserviceable supply valves, or inaccessible proudct or 

valves located in a loft space without suitable access.

For the latest Terms & Conditions please see:

www.tritonshowers.co.uk/terms

PLEASE NOTE PRODUCT REGISTRATION IS ONLY

AVAILABLE TO UNITS PURCHASED & INSTALLED IN THE UK

UK SERVICE POLICY

Triton Showers
Triton Road
Nuneaton
Warwickshire, CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Customer Experience: 024 7637 2222

Trade Installer Hotline: 024 7637 8344

www.tritonshowers.co.uk

E-mail: [email protected]

E-mail: [email protected]

Triton reserve the right to change product specifi cation without prior notice. E&OE. © TRITON SHOWERS 2022

Содержание 2181629F

Страница 1: ...BOX ALTERNATIVELY REGISTER BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation...

Страница 2: ...N COMPONENTS 1 DIMENSIONS 2 INTRODUCTION 3 PLUMBING WATER SYSTEM REQUIREMENTS 4 TYPICAL DOMESTIC INSTALLATIONS 5 6 PREPARING THE SHOWER 7 SITING OF THE SHOWER 7 INSTALLATION 8 12 LEAK TESTING 12 OPERA...

Страница 3: ...ush button mixer shower 1 MAIN COMPONENTS A Mixer shower B Riser rail C Wall brackets D Riser rail wall bracket E Slider F Hose not shown G Shower head not shown H Fixed shower head not shown C A D B...

Страница 4: ...mixer shower 2 780 1120mm 10 710mm 7 19mm 22mm 130x50mm 50 67mm 40mm 340mm 5 304mm 140mm 59mm 255x190mm DIMENSIONS All dimensions listed in this fitting book regarding the product and installation are...

Страница 5: ...old supply temperature C Equal to or less than 25 This mixer shower is designed for high pressure systems found in the UK For effective operation of the internal seals the maximum static pressure must...

Страница 6: ...he access point to the isolator Flush pipework to clear the system of debris and check for leaks before connecting to the mixer Commercial Applications For commercial applications in line filters are...

Страница 7: ...pply pressures exceed 5 bar running An expansion vessel MAY be fitted and regularly maintained to prevent the shower mixer being damaged by excess pressures This may already be installed within the bo...

Страница 8: ...reducing valve must be set at the same value as the unvented package pressure reducing valve Note An additional expansion vessel may be required if a second pressure reducing valve is installed This d...

Страница 9: ...carefully covered to stop ingress of any debris while routing the supply pipework The mixer shower is suitable for exposed installation onto solid wall a stud partition wall dry lined wall or fixing t...

Страница 10: ...uld pass through the support studs or noggins via a suitably sized hole fig 6 Decide upon the mounting position of the brackets on the wall and mark the centres Check the mounting marks are level and...

Страница 11: ...the pipework is at rest against the depth of chasing the length of pipe protruding from the wall should be between 25mm MAXIMUM and 21mm MINIMUM from the face of the finished wall or tiles fig 11 Make...

Страница 12: ...cover taking care not to damage the glass Offer the mixer shower to the brackets checking that the sealing washers are in place and carefully tighten the nuts Ensure the distance from the centre of th...

Страница 13: ...and drill and plug the wall An appropriate drill bit should be used If the wall is brick plasterboard or a soft building block use appropriate wall plugs and screws should be used Secure the bracket t...

Страница 14: ...Remedy any leaks found FITTING THE SHOWER HEAD Screw the conical end of the hose to the shower head then locate the shower head into the slider Screw the fixed head to the riser fixed head rail Make...

Страница 15: ...RE CONTROL To adjust the water temperature rotate the temperature control to the desired temperature fig 21 To overcome the maximum temperature stop press the override button and turn DIVERTER CONTROL...

Страница 16: ...ntee user safety Rotate the temperature control checking the minimum and maximum showering temperatatures ADJUST THE MAXIMUM TEMPERATURE STOP SETTING on page 14 if required The following is recommende...

Страница 17: ...res The BuildCert TMV scheme recommends a maximum mixed water outlet temperatures of 41 C for showers The mixed water temperatures must never exceed 46 C The British Burns Association recommends 37 C...

Страница 18: ...of routine maintenance of the internal of the mixer shower will depend mainly on the water supply condition Experience of local conditions will dictate the intervals for inspection and in service test...

Страница 19: ...7 8 0 11 5 14 0 16 5 18 0 Overhead showe head flow rate l m 2 6 3 6 4 0 5 0 5 6 8 0 12 0 15 0 17 0 18 5 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comp...

Страница 20: ...water supply blocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1...

Страница 21: ...4 2 1 Inspect the inlet filters Clean if necessary 4 3 1 Turn off the mixer shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sur...

Страница 22: ...Push button mixer shower 20...

Страница 23: ...Push button mixer shower 21...

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Отзывы: