5
- XM095 V1.2 NR
1) Unscrew the 4 screws A, B
,
C and D on the bottom of the housing, holding the plate where the
lamp is underneath.
2) Gently pull the socket holder using the knob in the middle.
3) Carefully insert the lamp into the socket. Please remember there is only one way to insert the lamp.
Gently slide the lamp and its lamp holder back into place and fasten the 4 screws.
4) On the access plate there are 3 small screws marked 1, 2 and 3.which are used to adjust the lamp
holder in the lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get
the maximum light output as shown below.
Please remember the lamp is not a hot-restrike type, you must wait for approximately 15 minutes
after having turned off the lamp before you can turn it back on again.
b)
Mounting the device
The installation of the effect has to be built and constructed in a way that it can hold 10 times the
weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate
safety cable.
Never stand directly below the device when mounting, removing or servicing the fixture.
The operator has to make sure the safety relating and machine technical installations are approved by
an expert before taking the device into operation for the first time.