12
- XM095 V1.2 NR
Lamp on/off
With this function you can switch the lamp on or off via the Control Board.
• Select
"Lamp on/off"
by turning the encoder.
• Press the encoder, the display shows
“ON”
or
“OFF”
.
• Turn the encoder to select
“ON”
if you wish to strike the lamp or
“OFF”
in order to switch it off.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
Remark:
The menu Lamp On/Off is the software command only, the lamp can be striked successfully only when the
menu Lamp is set to ON and the actual temperature is lower than the limited value.
Lamp on/off when power on
With this function you can select if the lamp will be switched on when switching the power on. Select
“ON”
by
turning the encoder if you wish to enable this function or
“OFF”
if you don’t.
Lamp on via external controller
With this function you can select if you can switch the lamp on via an external controller (DMX-channel of internal
programs, value 64-79). Select
“ON”
by turning the encoder if you wish to enable this function or
“OFF”
if you
don’t.
Lamp off via external controller
With this function you can select if you can switch the lamp off via an external controller (DMX-channel of internal
programs, value 224-239). Select
“ON”
by turning the encoder if you wish to enable this function or
“OFF”
if you
don’t.
Lamp Off if no DMX
With this function you can select to switch off the lamp off automatically if there is no DMX signal). Select
“OFF”
by
turning the encoder if you wish to switch off the lamp automatically at once, Select
“19M”
by turning the encoder if
you wish to postpone to 19 minutes switch off the lamp automatically.
Lamp on at temp.
With this function you can set the inside temperature from which the projector will restrike the lamp after automatic
lamp shut off.
Lamp off at temp.
With this function you can set the inside temperature at which the projector will automatically switch the lamp off.
Turn the encoder to select the maximum inside temperature between 60° C and 159° C. Inside temperatures below 90°
C are not critical. 90° C and more should lead to the lamp being switched off. Please note that the outside temperature
should not exceed 45° C.
When the temperature around the lamp is higher than the preset value continuously up to 5 minutes, the
lamp will be shut off automatically.
If the lamp be shut off automatically due to over heat, it can not be striked again automatically, it must be
turned on again by manually.
PERSONALITY
Status setting
Address via DMX
With this function, you can adjust the desired DMX-address via an external controller.
• Select
“Address via DMX”
by turning the encoder.
• Press the encoder, the display shows “ON” or “OFF”.
• Turn the encoder to select “ON” if you wish to enable this function or “OFF” if you don’t.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
• On the controller, set the DMX-value of channel 1 to "7".
• Set the DMX-value of channel 2 to "7"or "8". When set to "7" you can adjust the starting address between 1 and 255.
When set to "8" you can adjust the starting address between 256 and 511.