5
- XM010-V1.4-NR
1)
Unscrew the 3 screws (X, Y, Z) on the bottom of the housing, holding the plate where the lamp is
underneath. Carefully remove the metal plate.
2)
Carefully insert the lamp into the socket. Please remember there is only one way to insert the
lamp. Gently slide the lamp and its lamp holder back into place.
3)
On the access plate there are 3 screws marked A, Band C. which are used to adjust the lamp
holder in the lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get
the maximum light output as shown below.
X
Y
Z
Please remember the lamp is not a hot-restrike type, you must wait for approximately 15 minutes
after having turned off the lamp before you can turn it back on again.
!
CAUTION
Do not operate this device with open cover
b)
Inserting/Exchanging gobos
If you wish to use other forms and patterns as the standard-gobos, or if gobos are to be exchanged,
please follow the instructions below:
Remove the fixation-ring with an appropriate tool. Remove the gobo and insert the new gobo.
Press the fixation-ring together and insert it in front of the gobo.