24
- XM010-V1.4-NR
ERROR MESSAGE
When you turn on the fixture, it will make a reset first. The display may show “Xer” while there are problems with
one or more channels. “XX” stands for channel 1,2,3,4,5,6,8,9,12,14 who has the testing sensor for positioning .
For example, when the display shows “02Er”, it means there is some error in channel 2. If there are some errors on
channel 1, channel 2, channel 5 at the same time, you may see the error message “01Er”, “02Er”,”05Er” flash
repeated for 5 times, and then the fixture will generate a reset signal, all the stepper reset. If the fixture remain error
message after performing reset more than 3 times, it will detect whether the fixture has more than 3 errors. If the
fixture has more than 3 errors (including 3 errors), all the channels can not work properly; but if the fixture has less
than 3 errors, only the channels which have errors can not work properly, others can work as usual.
01Er:
(Color-wheel 1 error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main
PCB). The color wheel is not located in the default position after the reset.
02Er:
(Rotating gobo-wheel error ) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main
PCB). The rotating gobo-wheel is not located in the default position after the reset.
03Er:
(Gobo rotating error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main
PCB). The rotating gobo is not located in the default position after the reset.
04Er:
(Fix Gobo-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main
PCB). The fix gobo wheel is not located in the default position after the reset.
05Er:
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The yoke is not located in the default position after the reset.
06Er:
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The head is not located in the default position after the reset.
08Er:
(Prism-wheel error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main
PCB). The rotating gobo is not located in the default position after the reset.
09Er:
(Focus or zoom error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main
PCB). The focus is not located in the default position after the reset.
12Er:
(Iris error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The iris