PoE Configuration Status
State
Displays the current PoE mode.
Total Power (W)
Displays the total power that the Switch supports.
Total Power
Consumption (W)
Displays the total consuming power for all of the PDs.
Port
Display the Port No.
State
Displays the PoE state for the specific port (Enable/ Disable).
LLDP Alloc
Displays the status of allocated by LLDP MED.
Status
Displays the current status for the specific port (Searching or
Delivering).
Priority
Displays the PoE priority for the specific port for PD.
Class
The field displays the class mode which the PSE negotiate with the
PD on the specific port.
Max Power Limit
(W)
Displays the maximum PoE power for that specific port.
Power
Consumption (W)
Displays the consuming power for the specific port.
4.3.2.
PD Alive Check
The function has a global
state
configuration. If the global state configuration is enabled. The
Switch will check the configurations of every port.
If the port’s
state
is enabled, the Switch will send keep-a-live probe packet every
interval
time.
If the host cannot respond when the keep-a-live probe packet count is over the
retry times
, the
Switch performs the
action, reboot/alarm/all
to the Power Device
,
depending on the port’s
configuration.
Power OFF Time (sec):
When PD has been rebooted, the PoE port restored power after the specified time.
Default:15, range: 3-120 sec.
Startup Time (sec):
When PD has been start up, the Switch will wait Start up time to do PoE Auto Checking.
Default: 60, range: 30-600 sec.
Interval Time (sec):
Device will send checking message to PD each interval time.
Default: 30, range: 10-120sec.
Action:
The action when the failure detection.
All: S
end an alarm message to inform the administrator and then reboot the PD.
Alarm
: Just send an alarm message to inform the administrator.
None
: Keep Ping the remote PD but does nothing further.
Содержание NGI-S08C2POE8
Страница 1: ......
Страница 22: ...22...
Страница 134: ...134 Apply Click Apply to configure the settings Refresh Click Refresh to begin configuring this screen afresh...
Страница 136: ...136 Apply Click Apply to configure the settings Refresh Click Refresh to begin configuring this screen afresh...
Страница 138: ...138 Action Click Delete to remove a configured trap receiver station...