120
7.
Diagnostic
7.1.
Alarm
The feature displays if there are any abnormal situation need process immediately.
Alarm LED: On - When any alarm events happen.
The web pages show you the detail alarm reason.
7.1.1.
CLI Configuration
Node
Command
Description
enable
show alarm-info
This command displays alarm information.
7.1.2.
Web Configuration
Parameter
Description
Alarm Information
Alarm Status
This field indicates if there is any alarm events.
Alarm Reason(s)
This field displays all of the detail alarm events.
DIP switch Settings:
Storm
The field displays the current Storm Control DIP settings.
Disable – Storm Control controlled by user configurations.
Enable – Broadcast and DLF Storm control is enabled. And the
packet rate is 300 pps.
QoS
The field displays the current QoS DIP settings.
Disable – Port priority controlled by user configurations.
Enable – port 1 & 2 have higher priority.
P9 100Fx
The field displays the current port 9 100M-Full DIP settings.
Disable – port 9 speed controlled by user configurations.
Содержание NGI-S08C2POE8