Tripp Lite DC-to-AC Inverter/Chargers EMS Series Скачать руководство пользователя страница 5

5E

Configuration

Select Battery Type—REQUIRED

CAUTION:

The Battery Type DIP Switch setting must

match the type of batteries you connect, or your batteries
may be degraded or damaged over an extended period of
time. See “Battery Selection,” p. 7 for more information.

Battery Type

Switch Position

Gel Cell (Sealed) Battery

Up

Wet Cell (Vented) Battery

Down (factory setting)

Select Charger Enable/Inhibit 
(Model EMS1250UL only)

Switch is preset to ENABLE, which permits continuous
battery charging. If you are connecting the EMS1250UL
to batteries with a separate charger, you may set this
switch to INHIBIT to disable its built-in charger to 
prevent overcharging.

Voltage

Switch Position

Inhibit

Up

Enable

Down (factory setting)

Set Configuration DIP Switches

Using a small tool, set the Configuration DIP Switches (located on the front panel of your unit, see diagram) to optimize Inverter/Charger
operation depending on your application. 

A1

A2

A3

A4

INPUT C/B 10A

OUTPUT C/B 12A

B4

B3

B2

B1

A4

A3

A2

A1

Group B Dip Switches

Group A Dip Switches

Group A DIP Switches

Select Low AC Input Voltage Point for Switching to
Battery—OPTIONAL*

Voltage

Switch Position

105V

#A4 Up & #A3 Up

95V

#A4 Up & #A3 Down

85V

#A4 Down & #A3 Up

75V

#A4 Down & #A3 Down 
(factory setting)

* Most of your connected equipment will perform adequately when your Inverter/Charger’s High AC Input Voltage Point (DIP Switch #2 of Group A) is set to 135V and its Low AC Voltage Input
Point (DIP Switches #3 and #4 of Group A) are set to 95V. However, if the unit frequently switches to battery power due to momentary high/low line voltage swings that would have little effect on equip-
ment operation, you may wish to adjust these settings. By increasing the High AC Voltage Point and/or decreasing the Low AC Voltage Point, you will reduce the number of times your unit switches to
battery due to voltage swings.

Group B DIP Switches

Select Load Sharing—OPTIONAL

Your Inverter/Charger features a high-output battery charger that can draw a significant amount of AC power from your utility source or generator
when charging at its maximum rate. If your unit is supplying its full AC power rating to its connected heavy electrical loads at the same time
as this high charging occurs, the AC input circuit breaker could trip, resulting in the complete shut off of pass-through utility power.

To reduce the chance of tripping this breaker, Inverter/Chargers may be set to automatically limit the charger output. This keeps the sum of the unit’s
AC load and charge power within the circuit breaker rating. This charger-limiting function has four settings, allowing you to reduce the charger’s
draw lower and lower, as needed, if the AC input circuit breaker keeps tripping under the normal AC loads of devices you have connected
downline from the unit. The figures on the next page show how to set your DIP Switches to determine how heavy the connected load can
be on your Inverter/Charger before charger-limiting begins.

A1

A2

A3

A4

A1

A2

A3

A4

A1

A2

A3

A4

A1

A2

A3

A4

A1

A2

A3

A4

B2

B1

A1

A2

A3

A4

ENABLE

INHIBIT

Select High AC Input Voltage Point 
for Switching to Battery—OPTIONAL*
(Models EMS1012UL & EMS2012UL)

Voltage

Switch Position

145V

Up

135V

Down (factory setting)

A1

A2

A3

A4

135V

145V

A2

Содержание DC-to-AC Inverter/Chargers EMS Series

Страница 1: ... Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Protection Battery Charge Conserver Load Sense Battery Temperature Sensing High Efficiency DC to AC Inversion Better for You Quiet Simple Maintenance Free Operation Multi Function Lights Switches Dead Battery Startup Ignition Interlock In Out Swap Protection Moistur...

Страница 2: ...anty You may experience uneven performance results if you connect a surge suppressor line conditioner or UPS system to the output of the Inverter Charger Operation Warnings Your Inverter Charger does not require routine maintenance Do not open the device for any reason There are no user serviceable parts inside Potentially lethal voltages exist within the Inverter Charger as long as the battery su...

Страница 3: ... 10 for connection instructions Hardwire AC Input Output Terminal Strip not on corded models securely connects the Inverter Charger to vehicle electrical system See page 10 for connection instructions Resettable Circuit Breakers protect your Inverter Charger against damage due to overload See page 4 for resetting instructions Remote Control Module Connector allows remote monitoring and control wit...

Страница 4: ...t you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow Indicator This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery supplied inverted AC power in the absence of a utility generator source or in over under voltage situations This light will be off ...

Страница 5: ...ches to battery power due to momentary high low line voltage swings that would have little effect on equip ment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Select Load Sharing OPTIONAL Your Inverter Charg...

Страница 6: ...ill be detected causing the inverter to stay off until the new minimum load is reached Note the factory setting for the control is fully clockwise However based on the threshold load to which you d like the inverter to respond you should adjust the control counterclockwise to reduce its sensitivity until the inverter is active only when connected equipment or appliances are actually in use Connect...

Страница 7: ... Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or genera tor supplied AC power Compensate for inefficiency by multiplying this number by 1 2 This will give you a r...

Страница 8: ...ntal surface leaving the heads slightly raised Slide the Inverter Charger forward over the fasteners to engage the mounting feet molded on the front of the Inverter Charger cabinet Install and tight en two user supplied 6 mm fasteners into the mounting feet molded on the rear of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space be...

Страница 9: ...harger See your unit s Specifications Sheet for fuse requirements See diagrams below for proper fuse placement Battery Connection Vehicular Your Inverter Charger s Nominal DC Input Voltage must match the voltage of your battery or batteries 12 Volts in most vehicular applications Although it is possible to connect your Inverter Charger to the main battery within your vehicle s electrical system in...

Страница 10: ... either utility genera tor pass through power or inverter power simply plug your equipment into the Inverter Charger s AC receptacles Any equipment you con nect to it will benefit from your Inverter Charger s built in ISOBAR surge protection Warning Consult a qualified electrician and follow all applicable electrical codes and requirements for hardwire connection Disconnect both DC input and AC ut...

Страница 11: ...s direct indirect special incidental or consequential to the Inverter Charger incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Inverter Chargers shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the Inverter Charger is within th...

Страница 12: ...r assistance Charger Enable Inhibit Switch inadvertently set to INHIBIT Set Charger Enable Inhibit Switch to ENABLE Input circuit breaker is tripped Reset circuit breaker All Three Battery Indicator Lights Battery is excessively discharged Use an auxiliary charger to raise battery voltage Check external Are Slowly Flashing battery connections and fuse Unit automatically resets when Second Flashes ...

Страница 13: ...city DC 55 A 14 A 55 A 14 A 100 A 25 A Input Current AC 11 5 A 11 A 20A LINE VAC OPERATION Common Specifications for All Models Minimum Input Volts Transfer to Battery Selectable 75 85 95 or 105 VAC Maximum Input Volts Transfer to Battery Selectable 135 or 145 VAC Input Frequency Nominal 60 Hz 10 Maximum Input AC Current Continuous Charger at Maximum 12 A 12 A 38 A Maximum Bypass AC Current load c...

Отзывы: