Tripp Lite DC-to-AC Inverter/Chargers EMS Series Скачать руководство пользователя страница 2

2E

Important Safety Instructions

SAVE THESE  INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite
Inverter/Chargers.

Location Warnings

• Install your Inverter/Charger (whether for a mobile or stationary application) in a location or compartment that minimizes exposure to 

heat, dust, direct sunlight and moisture.

• Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short-circuit 

and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might 
accumulate. Mounting should be in the driest location available.

• Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. The heavier the load of connected 

equipment, the more heat will be generated by the unit.

• Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.

• Do not install near flammable materials, fuel or chemicals.

• Install EMS Inverter/Chargers in land vehicles only.

Battery Connection Warnings

• The Inverter/Charger will not operate (with or without utility power) until batteries are connected.

• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.

• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be 

installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some 
ventilation to outside air. 

• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.

• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury 

or property damage could result.

Equipment Connection Warnings

• In life support applications where a malfunction or failure of a Tripp Lite EMS Inverter/Charger could result in failure of, or

significantly alter the performance of, a life support device or any medical device critical to a patient's health, such devices 
should be provided with at least one backup power source by the ambulance operator.

• Corded models: Do not modify the Inverter/Charger’s plug or receptacle in a way that eliminates its ground connection. Do not use 

power adapters that will eliminate the plug’s ground connection.

• Connect your Inverter/Charger only to a properly grounded AC power outlet or hardwired source. Do not plug the unit into itself; this 

will damage the device and void your warranty.

• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of 

the Inverter/Charger.

Operation Warnings

• Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user-serviceable parts inside.

• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any 

service work, the battery supply and AC input connection (if any) should therefore be disconnected.

• Do not connect or disconnect batteries while the Inverter/Charger is operating from the battery supply. Dangerous arcing may result.

Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a period of 18 months from the date of retail purchase by end user.

Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty you must obtain a Returned Material
Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service center with transportation charges
prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been dam-
aged by accident, negligence or misapplication or has been altered or modified in any way, including opening of the unit’s casing for any reason. This warranty applies only to the original pur-
chaser who must have properly registered the product within 10 days of purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the retail purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE
USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment,
loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Limited Warranty

WARRANTY REGISTRATION

Visit www.tripplite.com/warranty to 
register the warranty of your new 
Tripp Lite product. You'll be automatically
entered into a drawing for a chance to
win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited.
Some restrictions apply. See website for details.

Содержание DC-to-AC Inverter/Chargers EMS Series

Страница 1: ... Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Protection Battery Charge Conserver Load Sense Battery Temperature Sensing High Efficiency DC to AC Inversion Better for You Quiet Simple Maintenance Free Operation Multi Function Lights Switches Dead Battery Startup Ignition Interlock In Out Swap Protection Moistur...

Страница 2: ...anty You may experience uneven performance results if you connect a surge suppressor line conditioner or UPS system to the output of the Inverter Charger Operation Warnings Your Inverter Charger does not require routine maintenance Do not open the device for any reason There are no user serviceable parts inside Potentially lethal voltages exist within the Inverter Charger as long as the battery su...

Страница 3: ... 10 for connection instructions Hardwire AC Input Output Terminal Strip not on corded models securely connects the Inverter Charger to vehicle electrical system See page 10 for connection instructions Resettable Circuit Breakers protect your Inverter Charger against damage due to overload See page 4 for resetting instructions Remote Control Module Connector allows remote monitoring and control wit...

Страница 4: ...t you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow Indicator This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery supplied inverted AC power in the absence of a utility generator source or in over under voltage situations This light will be off ...

Страница 5: ...ches to battery power due to momentary high low line voltage swings that would have little effect on equip ment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Select Load Sharing OPTIONAL Your Inverter Charg...

Страница 6: ...ill be detected causing the inverter to stay off until the new minimum load is reached Note the factory setting for the control is fully clockwise However based on the threshold load to which you d like the inverter to respond you should adjust the control counterclockwise to reduce its sensitivity until the inverter is active only when connected equipment or appliances are actually in use Connect...

Страница 7: ... Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or genera tor supplied AC power Compensate for inefficiency by multiplying this number by 1 2 This will give you a r...

Страница 8: ...ntal surface leaving the heads slightly raised Slide the Inverter Charger forward over the fasteners to engage the mounting feet molded on the front of the Inverter Charger cabinet Install and tight en two user supplied 6 mm fasteners into the mounting feet molded on the rear of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space be...

Страница 9: ...harger See your unit s Specifications Sheet for fuse requirements See diagrams below for proper fuse placement Battery Connection Vehicular Your Inverter Charger s Nominal DC Input Voltage must match the voltage of your battery or batteries 12 Volts in most vehicular applications Although it is possible to connect your Inverter Charger to the main battery within your vehicle s electrical system in...

Страница 10: ... either utility genera tor pass through power or inverter power simply plug your equipment into the Inverter Charger s AC receptacles Any equipment you con nect to it will benefit from your Inverter Charger s built in ISOBAR surge protection Warning Consult a qualified electrician and follow all applicable electrical codes and requirements for hardwire connection Disconnect both DC input and AC ut...

Страница 11: ...s direct indirect special incidental or consequential to the Inverter Charger incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Inverter Chargers shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the Inverter Charger is within th...

Страница 12: ...r assistance Charger Enable Inhibit Switch inadvertently set to INHIBIT Set Charger Enable Inhibit Switch to ENABLE Input circuit breaker is tripped Reset circuit breaker All Three Battery Indicator Lights Battery is excessively discharged Use an auxiliary charger to raise battery voltage Check external Are Slowly Flashing battery connections and fuse Unit automatically resets when Second Flashes ...

Страница 13: ...city DC 55 A 14 A 55 A 14 A 100 A 25 A Input Current AC 11 5 A 11 A 20A LINE VAC OPERATION Common Specifications for All Models Minimum Input Volts Transfer to Battery Selectable 75 85 95 or 105 VAC Maximum Input Volts Transfer to Battery Selectable 135 or 145 VAC Input Frequency Nominal 60 Hz 10 Maximum Input AC Current Continuous Charger at Maximum 12 A 12 A 38 A Maximum Bypass AC Current load c...

Отзывы: