background image

Specifications

MODEL NUMBER:

EMS1012UL

EMS1250UL

EMS2012UL

Series Number:

AGAP100012MV3

AGAP5094

AGAP200012MV3

AC Input Connection:

Input Cord

Input Cord

Hardwire

INVERTER

Common Specifications for All Models 

• DC Input Volts (Nominal): 12 VDC  • DC Input Voltage Range: 10 - 15 VDC  • Output Volts (Nominal): 120 VAC, ± 5%  • Output Frequency (Nominal): 60 Hz, ± 0.5% 

• Efficiency: 88% to 94% depending on load and temperature

Tripp Lite Inverter/Chargers include a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users
to set the minimum load level at which the unit’s inverter turns on. Users can significantly reduce the No Load DC Input Current
(approximately 1 A to 3 A for all models) to a very low amp level with the use of this control.

Continuous Power (@ 20 C):

1000

1250

2000

OverPower™ Peak Surge Power:*

1500

1875

3000

Double Boost™ Peak Surge Power:*

2000

2500

4000

Maximum Output AC Current (Continuous):

8.3 A

10.4 A

16.7 A

UL-Recognized DC Fuse Required:

200 A

200 A

400 A

DC Input Current @ Nominal V DC 

Full Load

95 A

127 A

190 A

BATTERY CHARGER 

Common Specifications for All Models 

• Acceptance Volts VDC: Selectable 14.4 V** / 14.2 V Wet** / Gel   • Float Volts DC (w/gel): 13.3 V (13.6 V)  • Input Volts (Nominal): 120 VAC

Charging Capacity DC:

55 A**/14 A

55 A** / 14 A

100 A**/25 A

Input Current AC:

11.5 A

11 A

20A

LINE VAC OPERATION

Common Specifications for All Models 

• Minimum Input Volts (Transfer to Battery): Selectable 75,** 85, 95 or 105 VAC  • Maximum Input Volts (Transfer to Battery): Selectable 135** or 145 VAC

• Input

Frequency (Nominal): 60 Hz, ±10%

Maximum Input AC Current (Continuous, Charger at Maximum):

12 A

12 A

38 A

Maximum Bypass AC Current (load circuit breaker limited):

12 A

12 A

20 A

* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting. 

Not applicable to Model EMS1250UL; switches select Charger Enable/Charger Inhibit.

The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice. 

Note on Labeling  

Two symbols are used on the EMS labels.

V~

: AC Voltage    

V

: DC Voltage

Inverter/Charger DC Volt: 12

Wire Gauge

Watts

6

4

2

0

00 (2/0)

500

15 ft

25 ft

39 ft

62 ft

79 ft

700

11 ft

18 ft

28 ft

44 ft

56 ft

1000

N/R

12 ft

20 ft

31 ft

39 ft

2000

N/R

N/R

N/R

16 ft

20 ft

2400

N/R

N/R

N/R

13 ft

16 ft

3000

N/R

N/R

N/R

10 ft

13 ft

Minimum Recommended Cable Sizing Chart

*

Use in conjunction with DC wiring connection instructions in the Battery Connection section.

* N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. the shorter the cable, the better the performance)

200412021  93-2404

Содержание DC-to-AC Inverter/Chargers EMS Series

Страница 1: ... Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Protection Battery Charge Conserver Load Sense Battery Temperature Sensing High Efficiency DC to AC Inversion Better for You Quiet Simple Maintenance Free Operation Multi Function Lights Switches Dead Battery Startup Ignition Interlock In Out Swap Protection Moistur...

Страница 2: ...anty You may experience uneven performance results if you connect a surge suppressor line conditioner or UPS system to the output of the Inverter Charger Operation Warnings Your Inverter Charger does not require routine maintenance Do not open the device for any reason There are no user serviceable parts inside Potentially lethal voltages exist within the Inverter Charger as long as the battery su...

Страница 3: ... 10 for connection instructions Hardwire AC Input Output Terminal Strip not on corded models securely connects the Inverter Charger to vehicle electrical system See page 10 for connection instructions Resettable Circuit Breakers protect your Inverter Charger against damage due to overload See page 4 for resetting instructions Remote Control Module Connector allows remote monitoring and control wit...

Страница 4: ...t you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow Indicator This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery supplied inverted AC power in the absence of a utility generator source or in over under voltage situations This light will be off ...

Страница 5: ...ches to battery power due to momentary high low line voltage swings that would have little effect on equip ment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Select Load Sharing OPTIONAL Your Inverter Charg...

Страница 6: ...ill be detected causing the inverter to stay off until the new minimum load is reached Note the factory setting for the control is fully clockwise However based on the threshold load to which you d like the inverter to respond you should adjust the control counterclockwise to reduce its sensitivity until the inverter is active only when connected equipment or appliances are actually in use Connect...

Страница 7: ... Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or genera tor supplied AC power Compensate for inefficiency by multiplying this number by 1 2 This will give you a r...

Страница 8: ...ntal surface leaving the heads slightly raised Slide the Inverter Charger forward over the fasteners to engage the mounting feet molded on the front of the Inverter Charger cabinet Install and tight en two user supplied 6 mm fasteners into the mounting feet molded on the rear of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space be...

Страница 9: ...harger See your unit s Specifications Sheet for fuse requirements See diagrams below for proper fuse placement Battery Connection Vehicular Your Inverter Charger s Nominal DC Input Voltage must match the voltage of your battery or batteries 12 Volts in most vehicular applications Although it is possible to connect your Inverter Charger to the main battery within your vehicle s electrical system in...

Страница 10: ... either utility genera tor pass through power or inverter power simply plug your equipment into the Inverter Charger s AC receptacles Any equipment you con nect to it will benefit from your Inverter Charger s built in ISOBAR surge protection Warning Consult a qualified electrician and follow all applicable electrical codes and requirements for hardwire connection Disconnect both DC input and AC ut...

Страница 11: ...s direct indirect special incidental or consequential to the Inverter Charger incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Inverter Chargers shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the Inverter Charger is within th...

Страница 12: ...r assistance Charger Enable Inhibit Switch inadvertently set to INHIBIT Set Charger Enable Inhibit Switch to ENABLE Input circuit breaker is tripped Reset circuit breaker All Three Battery Indicator Lights Battery is excessively discharged Use an auxiliary charger to raise battery voltage Check external Are Slowly Flashing battery connections and fuse Unit automatically resets when Second Flashes ...

Страница 13: ...city DC 55 A 14 A 55 A 14 A 100 A 25 A Input Current AC 11 5 A 11 A 20A LINE VAC OPERATION Common Specifications for All Models Minimum Input Volts Transfer to Battery Selectable 75 85 95 or 105 VAC Maximum Input Volts Transfer to Battery Selectable 135 or 145 VAC Input Frequency Nominal 60 Hz 10 Maximum Input AC Current Continuous Charger at Maximum 12 A 12 A 38 A Maximum Bypass AC Current load c...

Отзывы: