10-6
EMPRESS
10.2.4 GENERATOR OPERATION
1.
Controls:
The generator switches are located:
a. On the dash board, within easy reach
from the driver's seat.
b. Above the main entrance door, part of
the main control panel.
The generator starter does not draw current
from the engine batteries so the ignition does
not have to be on.
2.
Starting:
a. See Generator Manufacturer's Manu-
al for specifi c instructions.
b. Disconnect all electrical loads. (Turn
off all lights, appliances, equipment,
etc.).
c. Press generator start button, hold
until engine is running, then release.
d. A diesel generator will run approxi-
mately one minute before power will
be available. On gasoline generators,
allow the engine on the generator to
start and run smoothly before operat-
ing electrical appliances.
e. Be familiar with the output capacity
and capability of your generator.
f. Be careful not to overload the genera-
tor.
3.
Stopping:
a. Turn off lights and all appliances
before shutting off engine. Let the
engine run at no-load for a few min-
utes to allow the engine to cool down.
b. Press the OFF switch and hold until
engine comes to a complete stop.
Dash Board Switch
Hallway
GENERATOR CONTROLS
CAUTION
Overloading the generator for
long periods of time can cause
high temperatures that could
result in damage to the genera-
tor windings. Keep electrical
loads within the wattage ratings
specifi ed in your manual.
Содержание EMPRESS SERIES
Страница 1: ...EMPRESS SERIES OWNER S MANUAL Experience the Difference...
Страница 3: ...Printed in Canada...
Страница 83: ...10 10 EMPRESS 10 5 ELECTRICAL SCHEMATICS TYPICAL...
Страница 84: ...10 11 EMPRESS 10 6 FUSE PANELS 10 6 1 12 VOLT DC 12 VOLT PANEL 10 6 2 50 AMP AC 50 AMP PANEL...
Страница 102: ...12 12 EMPRESS 12 4 2 PLUMBING SCHEMATICS TYPICAL DRAINAGE SYSTEM...