13-4
EMPRESS
13.6 LP GAS FURNACE
The motorhome utilizes a central unit heating system.
The furnace is controlled by the climate control cent-
er. The device located in the galley area, controls the
furnace, roof air conditioner, or air conditioner heat
strip. The signature product uses two furnaces and
the controls for this second furnace is located in the
bedroom. Units equiped with a dual air Conditioner
system may have a zone temperature sensor located
in the bedroom. Please consult the climate control
center manual in the Owner's Information Package
for detailed instructions on operation.
The furnace(s) has no pilot light but is ignited by a
direct spark ignition system. No manual lighting is
required.
1.
To Start Up:
a. Close the LP gas tank valve.
b. Slide the thermostat switch from off to
heat.
c. Set the thermostat above room temperature
to start the blower. There will be a slight
delay before the blower comes on. Allow
the blower to run for 5 minutes to purge the
combustion chamber.
d. Move thermostat lever below room tempera-
ture. The blower will continue running for
about 2 minutes.
e. After the blower stops, open the LP gas tank
valve.
f. Set thermostat to desired temperature. If set
above current room temperature, the blower
will come on.
g. After about 30 seconds, the automatic igni-
tion device will light the burner. Do not at-
tempt to light the burner manually.
h. There should be warm air coming from the
heating ducts. If the burner fails to light,
repeat steps a - g.
i. If the burner fails to ignite after 3 attempts,
slide the thermostat to the off position, close
IMPORTANT
After the initial start-up the furnace will
automatically cycle on and off as it delivers
the required heat. The thermostat should
be in the heat position.
2.
To Shut Down:
a. Slide the thermostat to the off position.
b. Close the LP gas tank valve.
For additional information and instructions, refer to
the furnace manufacturer's manual.
CLIMATE CONTROL
Control
Zone Temperature Sensor
Содержание EMPRESS SERIES
Страница 1: ...EMPRESS SERIES OWNER S MANUAL Experience the Difference...
Страница 3: ...Printed in Canada...
Страница 83: ...10 10 EMPRESS 10 5 ELECTRICAL SCHEMATICS TYPICAL...
Страница 84: ...10 11 EMPRESS 10 6 FUSE PANELS 10 6 1 12 VOLT DC 12 VOLT PANEL 10 6 2 50 AMP AC 50 AMP PANEL...
Страница 102: ...12 12 EMPRESS 12 4 2 PLUMBING SCHEMATICS TYPICAL DRAINAGE SYSTEM...