Date: April, 2016 Doc No: PS-M-0433 Ver. A Page - 8 - of 10
7.
MODULE WIRING
Each module has two 4mm
2
diameter type standard 90°C sunlight resistant output cables each terminated with plug & play
connectors. This cable is suitable for applications where wiring is exposed to the direct rays of the Sun. We recommend that
all wiring and electrical connections comply with the appropriate national electrical code.
For field connections, use the minimum 4mm
2
diameter copper wires insulated for a minimum of 90°C and Sunlight
resistant as well.
The minimum and maximum outer cable diameters of the cable are 5 to 7mm. Refer to Datasheet Specifications for the
maximum electrical rating of series fuse.
8.
MODULE TILT ANGLE
Trina Solar PV modules connected in series should be installed at the same orientation and angle. Different orientation or
angle may cause loss of output power because each module may be exposed to different amounts of solar irradiation.
Trina Solar PV modules produce the most power when they are perpendicular to incoming sunlight. For installations where
the PV modules are attached to a permanent structure, the PV modules should be tilted for optimum winter performance.
The module tilt angle is measured between the solar modules and the ground. Optimal tilting of PV module is almost the
same as the latitude of installation location.
SPV module Tilt angle
9.
MECHANICAL DRAWING OF PV MODULE
For 60 cell Duomax module