Date: April, 2016 Doc No: PS-M-0433 Ver. A Page - 4 - of 10
4.
PRODUCT IDENTIFICATION
We recommend that you take note of the unique serial number on each module.
5.
ENVIRONMENTAL CONDITIONS AND SITE SELECTION
5.1
CLIMATE CONDITION
Install Trina Solar Crystalline series modules in the following conditions:
Ambient temperature: -40°C to +40°C
Operating temperature: -40°C to +85°C
Storage temperature: -20°C to +40°C
Humidity: below 85RH%
Mechanical Load Pressure*: 5400Pa Max from the front side, and 2400Pa from the rear.
* Mechanical load bearing (include wind and snow loads) of the module is based on Trina Solar mounting methods. A
professional system installer must be responsible for the mechanical load calculation based on the system design.
5.2
SITE SELECTION
1.
In most applications, Trina Solar PV modules should be installed in a location where they will receive maximum
sunlight throughout the year.
2.
Modules should not be shaded by buildings, trees, chimney, etc. at any time of the day.
3.
Do not install in corrosive environments, such as beaches or landfill that can be easily flooded.
4.
Do not install PV modules in a location where modules could be immersed in water or continually exposed to water
from a sprinkler or fountain.
5.
Do not install PV modules over naked flames or flammable materials.
6.
Interspaces, the clearance between the module edge and surface of the wall or roof, of at least 115mm is required to
prevent wiring damage and to allow air to circulate behind the module.
6.
MOUNTING INSTRUCTIONS—TRINA HOOK
The module is considered to be in compliance with IEC&UL 1703 only when the module is mounted in the manner
specified by the mounting instructions below. This mounting is using Trina Hooks, alternate mountings are available.
6.1
COMPONENTS OVERIEW
These components are only for use in the installation example in this section
Components Name
Overview
Description
M8/M10 Hexagon bolts,
M8/M10 nut,
Spring
washer
Material: SUS 304
Used to connect
modules together
Hook
Material:
Aluminum alloy 6063
Used to connect
module and
Racking